Electric trucks pantograph-catenary interaction condition monitoring method based on semantic segmentation network and linear fitting

Abstract The pantograph-catenary system (PCS) in dual-source electric trucks is crucial for maintaining a stable connection to the power grid, which directly impacts power quality. Ensuring reliable contact between the pantograph and catenary requires accurate detection of the contact point (CPT). However, existing CPT detection methods designed for trains are not well-suited for electric trucks due to differences in structural design. To address this challenge, this paper proposes a novel CPT detection method that integrates semantic segmentation and linear fitting techniques. Firstly, we introduce a lightweight Pantograph and Contact Line Segmentation Network (PCSN), which accurately extracts the regions of the pantograph and contact line. Secondly, a position correction algorithm combined with a least-squares linear fitting technique is employed to detect the CPT of electric trucks. Experimental results demonstrate that the proposed method achieves a detection error within ±5 pixels. In terms of processing speed, it reaches 76.9 FPS on an RTX 3080 GPU, 47.13 FPS on an Intel I9-12900 CPU, and 11.63 FPS on an embedded Jetson TX2 device.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2024-10-25
DOI
https://doi.org/10.1088/1402-4896/ad8b7d
Citations
3
Primary Topic
Electrical Contact Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.64

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electric trucks pantograph-catenary interaction condition monitoring method based on semantic segmentation network and linear fitting

Zhicheng Feng, Zhichao Chen, Jie Yang, Fan Li
3 citations
Physica Scripta
Electrical Contact Performance and Analysis
0.64
article

Electric trucks pantograph-catenary interaction condition monitoring method based on semantic segmentation network and linear fitting

Zhicheng Feng, Zhichao Chen, Jie Yang, Fan Li
article en
3 citations

Abstract

Abstract The pantograph-catenary system (PCS) in dual-source electric trucks is crucial for maintaining a stable connection to the power grid, which directly impacts power quality. Ensuring reliable contact between the pantograph and catenary requires accurate detection of the contact point (CPT). However, existing CPT detection methods designed for trains are not well-suited for electric trucks due to differences in structural design. To address this challenge, this paper proposes a novel CPT detection method that integrates semantic segmentation and linear fitting techniques. Firstly, we introduce a lightweight Pantograph and Contact Line Segmentation Network (PCSN), which accurately extracts the regions of the pantograph and contact line. Secondly, a position correction algorithm combined with a least-squares linear fitting technique is employed to detect the CPT of electric trucks. Experimental results demonstrate that the proposed method achieves a detection error within ±5 pixels. In terms of processing speed, it reaches 76.9 FPS on an RTX 3080 GPU, 47.13 FPS on an Intel I9-12900 CPU, and 11.63 FPS on an embedded Jetson TX2 device.

Physica ScriptaVol. 99(12)
Ganzhou People's Hospital (CN), Jiangxi Provincial People's Hospital (CN), Jiangxi University of Science and Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 35%
Electrical Contact Performance and Analysis
0.64
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.