Assessing the PV-integrated south facade in mitigating the BIPV system oversupply

The substantial increase in photovoltaic (PV) power penetration, anticipated in the coming years, will pose significant challenges related to managing the inherent fluctuations in power generation. To address these challenges, this study evaluated the integration of PV-louvers into the south façade as a potential solution. By serving as both shading devices and solar power generators, PV-louvers offered a promising approach to mitigating curtailment, optimizing energy efficiency, and enhancing grid reliability. Simulations conducted across 9 ASHRAE climate zones, including very hot-humid, hot-humid, hot-dry, warm-humid, warm-dry, warm-marine, mixed-humid, mixed-dry and warm-marine revealed that south façade PV-louvers significantly reduced curtailment in very hot, hot, and warm climate zones, but were less effective in mixed-humid, mixed-dry and warm-marine climates. Statistical analysis confirmed the effectiveness of PV-louvers. An ANOVA analysis yielding an F-statistic of 8.61 and a very small p-value of approximately 4.62 × 10 − 20 confirmed statistically significant differences in curtailment performance between different typologies. In June, the south façade PV-louver (S1 typology) outperformed all other typologies and demonstrating its effectiveness in curtailment mitigation. Overall, PV-louvers offer a promising solution for addressing curtailment, particularly in cooling-dominant months, offering a viable solution for addressing curtailment during period that it is the most significant. • BIPV energy production and consumption were calculated in two scenarios: south facade PV louvers and roof-mounted PVs. • Simulations were done across 9 different ASHRAE climate zones. • Effectiveness of south façade PV-louvers and roof-mounted PVs in mitigating duck curve curtailment was investigated. • Statistical analyses were conducted to evaluate the effectiveness of BIPV typologies in reducing curtailment.

Authors

Institutions

Publication Details

Journal
Energy Reports
Published
2024-10-25
DOI
https://doi.org/10.1016/j.egyr.2024.10.023
Citations
7
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the PV-integrated south facade in mitigating the BIPV system oversupply

Hamideh Hossei, Kyoung Hee Kim
7 citations
Energy Reports
Photovoltaic System Optimization Techniques
0.72
article

Assessing the PV-integrated south facade in mitigating the BIPV system oversupply

Hamideh Hossei, Kyoung Hee Kim
article en
7 citations

Abstract

The substantial increase in photovoltaic (PV) power penetration, anticipated in the coming years, will pose significant challenges related to managing the inherent fluctuations in power generation. To address these challenges, this study evaluated the integration of PV-louvers into the south façade as a potential solution. By serving as both shading devices and solar power generators, PV-louvers offered a promising approach to mitigating curtailment, optimizing energy efficiency, and enhancing grid reliability. Simulations conducted across 9 ASHRAE climate zones, including very hot-humid, hot-humid, hot-dry, warm-humid, warm-dry, warm-marine, mixed-humid, mixed-dry and warm-marine revealed that south façade PV-louvers significantly reduced curtailment in very hot, hot, and warm climate zones, but were less effective in mixed-humid, mixed-dry and warm-marine climates. Statistical analysis confirmed the effectiveness of PV-louvers. An ANOVA analysis yielding an F-statistic of 8.61 and a very small p-value of approximately 4.62 × 10 − 20 confirmed statistically significant differences in curtailment performance between different typologies. In June, the south façade PV-louver (S1 typology) outperformed all other typologies and demonstrating its effectiveness in curtailment mitigation. Overall, PV-louvers offer a promising solution for addressing curtailment, particularly in cooling-dominant months, offering a viable solution for addressing curtailment during period that it is the most significant. • BIPV energy production and consumption were calculated in two scenarios: south facade PV louvers and roof-mounted PVs. • Simulations were done across 9 different ASHRAE climate zones. • Effectiveness of south façade PV-louvers and roof-mounted PVs in mitigating duck curve curtailment was investigated. • Statistical analyses were conducted to evaluate the effectiveness of BIPV typologies in reducing curtailment.

Energy ReportsVol. 12
University of North Carolina at Charlotte (US)
National Science Foundation
Sustainable cities and communities
Openalex Percentile: Top 35%
Photovoltaic System Optimization Techniques
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.