Flaw detection of railway catenary insulator based on DP-YOLOv5 algorithm with bright and dark channel enhancement

Abstract To ensure the timely detection of safety hazards in overhead transmission lines with railroad conductors and improve the accuracy of night insulator defect detection, this paper proposes the DP-YOLOv5 algorithm with dark and light channel enhancement optimization. It improves the night insulator image quality by introducing the dark and light channel enhancement algorithm, builds a lightweight network by combining the DP-BS module, and adds the Shuffle Attention module to enhance the feature extraction and ensure detection accuracy. At the same time, the EC-Loss loss function is used to optimize the prediction frame adjustment, accelerate the model convergence, and improve detection efficiency and accuracy. The simulation results show that the insulator dataset processed by DP-YOLOv5 has an accuracy of 95.3%, a recall of 94.8%, an average accuracy of 95.5%, and FLOPs of 219.3. Compared with YOLOv5, the mapped value is improved by 0.9%, the F1 is improved by 1%, and the model parameter and FLOPs are reduced by 48.8% and 50.8%, respectively.

Authors

Institutions

Publication Details

Journal
Physica Scripta
Published
2024-10-25
DOI
https://doi.org/10.1088/1402-4896/ad8b84
Citations
1
Primary Topic
Optical Systems and Laser Technology
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Flaw detection of railway catenary insulator based on DP-YOLOv5 algorithm with bright and dark channel enhancement

Lingzhi Yi, Jiangyong Liu, Lifu Luo, Haixiang She et al.
1 citations
Physica Scripta
Optical Systems and Laser Technology
0.21
article

Flaw detection of railway catenary insulator based on DP-YOLOv5 algorithm with bright and dark channel enhancement

Lingzhi Yi, Jiangyong Liu, Lifu Luo, Haixiang She, Tengfei Dong, Yahui Wang, S. Q. Luo
article en
1 citations

Abstract

Abstract To ensure the timely detection of safety hazards in overhead transmission lines with railroad conductors and improve the accuracy of night insulator defect detection, this paper proposes the DP-YOLOv5 algorithm with dark and light channel enhancement optimization. It improves the night insulator image quality by introducing the dark and light channel enhancement algorithm, builds a lightweight network by combining the DP-BS module, and adds the Shuffle Attention module to enhance the feature extraction and ensure detection accuracy. At the same time, the EC-Loss loss function is used to optimize the prediction frame adjustment, accelerate the model convergence, and improve detection efficiency and accuracy. The simulation results show that the insulator dataset processed by DP-YOLOv5 has an accuracy of 95.3%, a recall of 94.8%, an average accuracy of 95.5%, and FLOPs of 219.3. Compared with YOLOv5, the mapped value is improved by 0.9%, the F1 is improved by 1%, and the model parameter and FLOPs are reduced by 48.8% and 50.8%, respectively.

Physica ScriptaVol. 99(12)
Hunan University of Science and Technology (CN), Guangdong University of Technology (CN), Yunnan Investment Group (China) (CN), Xiangtan University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 47%
Optical Systems and Laser Technology
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Flaw detection of railway catenary insulator based on DP-YOLOv5 algorithm with bright and dark channel enhancement — Lingzhi Yi, Jiangyong Liu, et al. · Physica Scripta (2024) | TGRS Research Map | TGRS