Analysis Of Load Balance In 20 Kv Distribution Systems On Power Losses

Load balancing is one of the things that must be considered by reducing the value of voltage drops or power losses that occur in distribution channels. It is necessary to know the characteristics of the load in an area or area with a balanced supply so that each phase is burdened evenly. Calculating the voltage drop on the distribution network conductors, the voltage drop on the KBN09 Slawi feeder was calculated. What will be calculated here is from the line to the transformer furthest from the GI, namely from the three-phase 20 kV main line, single-phase branching. The results of power calculations from GI Kebasen Tegal show differences between R, S and T phases with three 20 kV phases in pre-balance and post-balance conditions. As written, the value for R wire is 82661.52 W, for S 52613 W, while for the T phase the value is 60127.06 W. Meanwhile, the calculation of power losses from GI Kebasen Tegal shows differences between the R, S and T phases with 1 phase voltage in the conditions before balance and after balanced. On the 3-phase line for the R wire, the power loss decreases from 34,198 W to 17,0425 W, for S it increases from 11,540 W to 19,077 W, while for the T phase the value remains 15,274 W.

Authors

Institutions

Publication Details

Journal
Journal of International Multidisciplinary Research
Published
2024-10-23
DOI
https://doi.org/10.62504/jimr892
Primary Topic
Power Line Communications and Noise
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis Of Load Balance In 20 Kv Distribution Systems On Power Losses

Ajub Ajulian ZM, Karnoto Karnoto, Bambang Winardi
Journal of International Multidisciplinary Research
Power Line Communications and Noise
article

Analysis Of Load Balance In 20 Kv Distribution Systems On Power Losses

Ajub Ajulian ZM, Karnoto Karnoto, Bambang Winardi
article en

Abstract

Load balancing is one of the things that must be considered by reducing the value of voltage drops or power losses that occur in distribution channels. It is necessary to know the characteristics of the load in an area or area with a balanced supply so that each phase is burdened evenly. Calculating the voltage drop on the distribution network conductors, the voltage drop on the KBN09 Slawi feeder was calculated. What will be calculated here is from the line to the transformer furthest from the GI, namely from the three-phase 20 kV main line, single-phase branching. The results of power calculations from GI Kebasen Tegal show differences between R, S and T phases with three 20 kV phases in pre-balance and post-balance conditions. As written, the value for R wire is 82661.52 W, for S 52613 W, while for the T phase the value is 60127.06 W. Meanwhile, the calculation of power losses from GI Kebasen Tegal shows differences between the R, S and T phases with 1 phase voltage in the conditions before balance and after balanced. On the 3-phase line for the R wire, the power loss decreases from 34,198 W to 17,0425 W, for S it increases from 11,540 W to 19,077 W, while for the T phase the value remains 15,274 W.

Journal of International Multidisciplinary ResearchVol. 2(10)
Diponegoro University (ID)
Affordable and clean energy
Openalex Percentile: Top 83%
Power Line Communications and Noise
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.