Evaluating the effect of partially polarized light sources on the point spread function in optical coherence tomography

Leveraging the polarization property of light to evaluate the birefringence of tissues as well as changes due to pathological conditions has been gaining interest over the past two decades with the introduction of different variants of optical coherence tomography (OCT) including polarization-sensitive OCT (PS-OCT) and cross-polarization OCT (CP-OCT). Because OCT sources are partially polarized, PS-OCT and CP-OCT generally require a linear polarizer and polarization-maintaining fibers to enable a linearly polarized input beam into the interferometer. While recent studies have suggested using an unpolarized input beam to reduce the system's complexity, the effect of unpolarized light on the point spread function (PSF) of OCT has not been fully studied. This work proposed a mathematical framework to evaluate the contribution of unpolarized light to the PSF of OCT. Simulation and experiments were performed for three OCT sources to assess the validity of the proposed model. Overall, simulations were in good agreement with experiments and revealed that unpolarized light introduced two additional reflectors into the reflectivity profile of the source, which were more pronounced in the cross-polarization configuration. This additional information can lead to misinterpretation of the birefringence of tissues in PS-OCT and CP-OCT. Their effect on image quality was evaluated in <i>ex vivo</i> corneal imaging of porcine eyeballs.

Authors

Publication Details

Journal
Journal of the Optical Society of America A
Published
2024-10-25
DOI
https://doi.org/10.1364/josaa.545407
Citations
1
Primary Topic
Optical Coherence Tomography Applications
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating the effect of partially polarized light sources on the point spread function in optical coherence tomography

Patrice Tankam, Xiao Liu
1 citations
Journal of the Optical Society of America A
Optical Coherence Tomography Applications
0.18
article

Evaluating the effect of partially polarized light sources on the point spread function in optical coherence tomography

Patrice Tankam, Xiao Liu
article en
1 citations

Abstract

Leveraging the polarization property of light to evaluate the birefringence of tissues as well as changes due to pathological conditions has been gaining interest over the past two decades with the introduction of different variants of optical coherence tomography (OCT) including polarization-sensitive OCT (PS-OCT) and cross-polarization OCT (CP-OCT). Because OCT sources are partially polarized, PS-OCT and CP-OCT generally require a linear polarizer and polarization-maintaining fibers to enable a linearly polarized input beam into the interferometer. While recent studies have suggested using an unpolarized input beam to reduce the system's complexity, the effect of unpolarized light on the point spread function (PSF) of OCT has not been fully studied. This work proposed a mathematical framework to evaluate the contribution of unpolarized light to the PSF of OCT. Simulation and experiments were performed for three OCT sources to assess the validity of the proposed model. Overall, simulations were in good agreement with experiments and revealed that unpolarized light introduced two additional reflectors into the reflectivity profile of the source, which were more pronounced in the cross-polarization configuration. This additional information can lead to misinterpretation of the birefringence of tissues in PS-OCT and CP-OCT. Their effect on image quality was evaluated in <i>ex vivo</i> corneal imaging of porcine eyeballs.

Journal of the Optical Society of America AVol. 41(12)
CooperVision
Openalex Percentile: Top 51%
Optical Coherence Tomography Applications
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.