Determination of Residual Dimethyl Sulfate in Cephalosporin Using HS-SPME/GC–MS

Dimethyl sulfate (DMS) is widely used in manufacturing process but because of its genotoxicity nature, it should be monitored at trace levels (1 μg/mL). It is complicated and difficult to quantify DMS in cephalosporin with traditional method. Herein, a method for quantifying residual DMS in cephalosporin was developed, without complex sample preprocessing, no need for a large amount of solvent, employing headspace solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Compared with polydimethylsiloxane (PDMS)/divinylbenzene and polyacrylate fibers, PDMS was more suitable for absorbing DMS. The research showed that the PDMS fiber should be changed after 50 adsorption-desorption cycles. Linear regression analysis of the calibration curve demonstrated a robust linear relationship, with R2 of 0.999, across a concentration range of 0.25 to 4.0 μg/mL. The method underwent rigorous validation for specificity, linearity, precision and accuracy. This method was proven effective in measuring DMS in complex matrices. The limits of detection and quantification for this method is 0.05 and 0.25 μg/mL, respectively, which has room for improvement.

Authors

Institutions

Publication Details

Journal
Journal of Chromatographic Science
Published
2024-10-11
DOI
https://doi.org/10.1093/chromsci/bmae054
Citations
2
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Residual Dimethyl Sulfate in Cephalosporin Using HS-SPME/GC–MS

Rongchun Lu
2 citations
Journal of Chromatographic Science
Pesticide Residue Analysis and Safety
0.70
article

Determination of Residual Dimethyl Sulfate in Cephalosporin Using HS-SPME/GC–MS

Rongchun Lu
article en
2 citations

Abstract

Dimethyl sulfate (DMS) is widely used in manufacturing process but because of its genotoxicity nature, it should be monitored at trace levels (1 μg/mL). It is complicated and difficult to quantify DMS in cephalosporin with traditional method. Herein, a method for quantifying residual DMS in cephalosporin was developed, without complex sample preprocessing, no need for a large amount of solvent, employing headspace solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). Compared with polydimethylsiloxane (PDMS)/divinylbenzene and polyacrylate fibers, PDMS was more suitable for absorbing DMS. The research showed that the PDMS fiber should be changed after 50 adsorption-desorption cycles. Linear regression analysis of the calibration curve demonstrated a robust linear relationship, with R2 of 0.999, across a concentration range of 0.25 to 4.0 μg/mL. The method underwent rigorous validation for specificity, linearity, precision and accuracy. This method was proven effective in measuring DMS in complex matrices. The limits of detection and quantification for this method is 0.05 and 0.25 μg/mL, respectively, which has room for improvement.

Journal of Chromatographic ScienceVol. 62(10)
University of Shanghai for Science and Technology (CN)
Clean water and sanitation
Openalex Percentile: Top 27%
Pesticide Residue Analysis and Safety
0.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.