Industrial experimental study on combustion characteristics and NOx emission characteristics of a 600 MWe wall‐fired boiler under ultra‐low excess air coefficient conditions

Abstract This paper aims to explore the effects of ultra‐low excess air coefficients on the combustion performance and NO x emission characteristics of coal‐fired boilers through industrial experiments conducted on a 600 MWe wall‐fired boiler. The results indicate that the burners demonstrate good ignition performance under different ultra‐low excess air coefficient conditions. As the excess air coefficient increases, the temperature in the main combustion zone rises, and the ignition distance of pulverized coal shortens. Under ultra‐low excess air coefficient conditions (such as 1.04), the unburned carbon content in fly ash reaches 5.50%, which is 3.23% higher than under the condition of 1.11, indicating poor pulverized coal burnout. When the excess air coefficient is close to the theoretical design value (such as 1.11), the carbon content in slag and the unburned carbon content in fly ash is relatively low (1.40% and 2.28%, respectively), indicating more complete combustion of pulverized coal. Additionally, the flue gas temperature at the air preheater outlet under this condition is relatively low; compared to the condition of an excess air coefficient of 1.07, the flue gas temperature is reduced by 6°C, thus reducing flue gas loss. Although the NO x concentration under the condition of an excess air coefficient of 1.11 is slightly higher, the quantity of cooling water is less. Flow field tracking of the powder verifies the flow path and characteristics of the primary air of the burners, and the results show that the primary air flow path of the burners is relatively concentrated, avoiding impingement on the water‐cooled walls and effectively preventing slagging issues on the water‐cooled walls. The research findings are of great significance for improving the operational performance and environmental protection level of coal‐fired boilers.

Authors

Institutions

Publication Details

Journal
Asia-Pacific Journal of Chemical Engineering
Published
2024-10-23
DOI
https://doi.org/10.1002/apj.3171
Citations
4
Primary Topic
Radiative Heat Transfer Studies
Type
article
Field-Weighted Citation Impact
1.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Industrial experimental study on combustion characteristics and NOx emission characteristics of a 600 MWe wall‐fired boiler under ultra‐low excess air coefficient conditions

Shuguang Ti, Shanshan Deng, Youjian Zhu, Ke Gao et al.
4 citations
Asia-Pacific Journal of Chemical Engineering
Radiative Heat Transfer Studies
1.50
article

Industrial experimental study on combustion characteristics and NOx emission characteristics of a 600 MWe wall‐fired boiler under ultra‐low excess air coefficient conditions

Shuguang Ti, Shanshan Deng, Youjian Zhu, Ke Gao, Zheng Li, Haopeng Wang, Jinhui Yang, Shang Gao, Zhi Yang
article en
4 citations

Abstract

Abstract This paper aims to explore the effects of ultra‐low excess air coefficients on the combustion performance and NO x emission characteristics of coal‐fired boilers through industrial experiments conducted on a 600 MWe wall‐fired boiler. The results indicate that the burners demonstrate good ignition performance under different ultra‐low excess air coefficient conditions. As the excess air coefficient increases, the temperature in the main combustion zone rises, and the ignition distance of pulverized coal shortens. Under ultra‐low excess air coefficient conditions (such as 1.04), the unburned carbon content in fly ash reaches 5.50%, which is 3.23% higher than under the condition of 1.11, indicating poor pulverized coal burnout. When the excess air coefficient is close to the theoretical design value (such as 1.11), the carbon content in slag and the unburned carbon content in fly ash is relatively low (1.40% and 2.28%, respectively), indicating more complete combustion of pulverized coal. Additionally, the flue gas temperature at the air preheater outlet under this condition is relatively low; compared to the condition of an excess air coefficient of 1.07, the flue gas temperature is reduced by 6°C, thus reducing flue gas loss. Although the NO x concentration under the condition of an excess air coefficient of 1.11 is slightly higher, the quantity of cooling water is less. Flow field tracking of the powder verifies the flow path and characteristics of the primary air of the burners, and the results show that the primary air flow path of the burners is relatively concentrated, avoiding impingement on the water‐cooled walls and effectively preventing slagging issues on the water‐cooled walls. The research findings are of great significance for improving the operational performance and environmental protection level of coal‐fired boilers.

Asia-Pacific Journal of Chemical EngineeringVol. 20(2)
Zhengzhou University of Light Industry (CN)
Openalex Percentile: Top 20%
Radiative Heat Transfer Studies
1.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.