Simultaneous quantification of serum symmetric dimethylarginine, asymmetric dimethylarginine and creatinine for use in a routine clinical laboratory

BackgroundSymmetric dimethylarginine (SDMA) and asymmetric dimethylarginine (ADMA) are naturally occurring amino acids classed as uraemic toxins by the European Uremic Toxins Work Group. SDMA is principally excreted through the kidneys and is a well-known renal function marker, and ADMA is a potent inhibitor of nitric oxide production. Here, we describe the development of a rapid and sensitive liquid chromatography tandem mass spectrometry method for simultaneous measurement of SDMA, ADMA and creatinine.MethodSerum samples were prepared by protein precipitation and dilution with acetonitrile prior to injection onto a Waters TQS-Micro. SDMA, ADMA, creatinine and their corresponding internal standard transitions were detected using multiple reaction monitoring after separation with a hydrophilic interaction liquid chromatography analytical column. Sample stability and intra-individual variation studies were also assessed following ethical approval.ResultsThe retention time for creatinine was 0.43, SDMA 1.10 and ADMA 1.14 min. Mean recovery for creatinine was 103%, SDMA was 100% and ADMA was 103%; matrix effects were minimal (<6%). Lower limit of quantitation for creatinine and SDMA/ADMA was 17.5 µmol/L and 0.1 µmol/L, respectively. Analytical imprecision showed a coefficient of variation <10% for all analytes across the working range of the assays. Intra-individual variation for creatinine was 4.7%, SDMA 7.5% and ADMA 7.6%.DiscussionWe have developed a rugged assay for measurement of SDMA, ADMA and creatinine by LC-MS/MS suitable for routine use. It is easy to perform owing to its simplicity and reproducibility. The stability of SDMA and ADMA pre- and post-centrifugation allows for their routine use without any special sample handling requirements.

Authors

Institutions

Publication Details

Journal
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Published
2024-10-24
DOI
https://doi.org/10.1177/00045632241298161
Primary Topic
Nitric Oxide and Endothelin Effects
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous quantification of serum symmetric dimethylarginine, asymmetric dimethylarginine and creatinine for use in a routine clinical laboratory

David Marshall, James Hawley, Brian George Keevil
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Nitric Oxide and Endothelin Effects
article

Simultaneous quantification of serum symmetric dimethylarginine, asymmetric dimethylarginine and creatinine for use in a routine clinical laboratory

David Marshall, James Hawley, Brian George Keevil
article en

Abstract

BackgroundSymmetric dimethylarginine (SDMA) and asymmetric dimethylarginine (ADMA) are naturally occurring amino acids classed as uraemic toxins by the European Uremic Toxins Work Group. SDMA is principally excreted through the kidneys and is a well-known renal function marker, and ADMA is a potent inhibitor of nitric oxide production. Here, we describe the development of a rapid and sensitive liquid chromatography tandem mass spectrometry method for simultaneous measurement of SDMA, ADMA and creatinine.MethodSerum samples were prepared by protein precipitation and dilution with acetonitrile prior to injection onto a Waters TQS-Micro. SDMA, ADMA, creatinine and their corresponding internal standard transitions were detected using multiple reaction monitoring after separation with a hydrophilic interaction liquid chromatography analytical column. Sample stability and intra-individual variation studies were also assessed following ethical approval.ResultsThe retention time for creatinine was 0.43, SDMA 1.10 and ADMA 1.14 min. Mean recovery for creatinine was 103%, SDMA was 100% and ADMA was 103%; matrix effects were minimal (<6%). Lower limit of quantitation for creatinine and SDMA/ADMA was 17.5 µmol/L and 0.1 µmol/L, respectively. Analytical imprecision showed a coefficient of variation <10% for all analytes across the working range of the assays. Intra-individual variation for creatinine was 4.7%, SDMA 7.5% and ADMA 7.6%.DiscussionWe have developed a rugged assay for measurement of SDMA, ADMA and creatinine by LC-MS/MS suitable for routine use. It is easy to perform owing to its simplicity and reproducibility. The stability of SDMA and ADMA pre- and post-centrifugation allows for their routine use without any special sample handling requirements.

Annals of Clinical Biochemistry International Journal of Laboratory MedicineVol. 62(2)
Manchester University NHS Foundation Trust (GB), Wythenshawe Hospital (GB)
Openalex Percentile: Top 74%
Nitric Oxide and Endothelin Effects
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.