Сравнение динамических характеристик пьезокерамических актуаторов, применяемых в вибродиагностике крупномасштабных конструкций

One of the effective methods of non-destructive testing of large-scale structures is active vibration diagnostics. It involves local dynamic impact on the structure and recording structural vibration response. Analysis of a set of responses recorded at different points allows determining the mechanical condition of an object under study. According to the method of active vibration diagnostics, dynamic influences are realized by special devices – actuators. Today, most widely used are piezoceramic actuators. As a rule, they are a piezoceramic plate embedded in the structure or located on its surface. Previously, the authors have proposed a piezoceramic actuator with attached mass, which is able to create more intense impact on the structure. In this work, numerical modeling is applied to evaluate the effectiveness of a modified device in comparison with traditional devices using a concrete slab and a model 4-story building as examples. Based on the results obtained, it is concluded that the elastic waves, excited by the actuators of three types mentioned here, are of significantly different intensity. The piezoceramic plate placed on the surface of the structure provides the wave with the lowest amplitude. It is 1.9 times smaller than for the plate embedded in the structure and 12 times smaller than for the plate with attached mass. The numerical experiment, which demonstrates the propagation of an elastic wave in the components of the model building, made it possible to evaluate the intensity of vibrations at different distances from a vibration source. For the actuator with attached mass, the amplitude of acceleration at the point placed at a distance of 1.7 meters from the actuator is 20 m/s2; 5.2 meters – 5 m/s2; 8.7 meters – 2 m/s2. These accelerations can be reliably measured by most modern accelerometers. Thus, a piezoceramic actuator with attached mass is the most promising device for active vibration diagnostics of large-scale concrete structures. The use of such actuators in the monitoring system reduces the total number of actuators and sensors due to increasing the distance between them.

Authors

Publication Details

Journal
Computational Continuum Mechanics
Published
2024-10-24
DOI
https://doi.org/10.7242/1999-6691/2024.17.3.31
Citations
1
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Сравнение динамических характеристик пьезокерамических актуаторов, применяемых в вибродиагностике крупномасштабных конструкций

G. Gusev, Р. В. Цветков, A. Shestakov, И. Н. Шардаков et al.
1 citations
Computational Continuum Mechanics
Structural Health Monitoring Techniques
0.26
article

Сравнение динамических характеристик пьезокерамических актуаторов, применяемых в вибродиагностике крупномасштабных конструкций

G. Gusev, Р. В. Цветков, A. Shestakov, И. Н. Шардаков, I. Glot, V. Yepin
article en
1 citations

Abstract

One of the effective methods of non-destructive testing of large-scale structures is active vibration diagnostics. It involves local dynamic impact on the structure and recording structural vibration response. Analysis of a set of responses recorded at different points allows determining the mechanical condition of an object under study. According to the method of active vibration diagnostics, dynamic influences are realized by special devices – actuators. Today, most widely used are piezoceramic actuators. As a rule, they are a piezoceramic plate embedded in the structure or located on its surface. Previously, the authors have proposed a piezoceramic actuator with attached mass, which is able to create more intense impact on the structure. In this work, numerical modeling is applied to evaluate the effectiveness of a modified device in comparison with traditional devices using a concrete slab and a model 4-story building as examples. Based on the results obtained, it is concluded that the elastic waves, excited by the actuators of three types mentioned here, are of significantly different intensity. The piezoceramic plate placed on the surface of the structure provides the wave with the lowest amplitude. It is 1.9 times smaller than for the plate embedded in the structure and 12 times smaller than for the plate with attached mass. The numerical experiment, which demonstrates the propagation of an elastic wave in the components of the model building, made it possible to evaluate the intensity of vibrations at different distances from a vibration source. For the actuator with attached mass, the amplitude of acceleration at the point placed at a distance of 1.7 meters from the actuator is 20 m/s2; 5.2 meters – 5 m/s2; 8.7 meters – 2 m/s2. These accelerations can be reliably measured by most modern accelerometers. Thus, a piezoceramic actuator with attached mass is the most promising device for active vibration diagnostics of large-scale concrete structures. The use of such actuators in the monitoring system reduces the total number of actuators and sensors due to increasing the distance between them.

Computational Continuum MechanicsVol. 17(3)
Sustainable cities and communities
Openalex Percentile: Top 44%
Structural Health Monitoring Techniques
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.