Investigation of Metoprolol Concentrations in Plasma Using Automated Sample Preparation and LC-MS/MS Detection

Metoprolol (MTP), a selective beta-1 adrenergic blocker, is commonly administered in the form of succinate or tartrate salts, depending on the pharmaceutical formulation. It is typically prescribed in oral forms as either immediate-release or extended-release tablets. This study describes a chromatographic method using automated sample clean-up and elution via a reversed-phase mechanism. A TurboFlow approach was applied with a Cyclone P column, and the elution was performed isocratically using a mobile phase of water and acetonitrile (0.1% v/v formic acid) within 4.5 min. Quantification of MTP was achieved using triple quadrupole mass spectrometry, with the transition m/z 268.1 → m/z 130.96 for metoprolol, while bisoprolol fumarate, the internal standard, was detected at m/z 326.3 → m/z 116.2. The method was validated according to bioequivalence guidelines. Selectivity was assessed by checking for potential interferences from blank samples or related compounds formed during sample preparation. Precision and accuracy were evaluated both within and between runs, with a maximum coefficient of variation (CV%) of 10.28 and a maximum relative error (ER%) of 5.38. Linearity was demonstrated over the range of 5 ng/L to 1000 ng/L, with a lower limit of quantification at 0.042 ng/L, made possible by injecting larger sample volumes. A matrix effect of 89% was considered acceptable when compared to standard solutions. Plasma concentrations of MTP were monitored in patients administered either 50 mg or 100 mg doses. For the 50 mg dose, plasma levels reached up to 34 μg/L, while the 100 mg dose produced concentrations ranging from 3.56 to 50.81 μg/L. Although the higher dose generally resulted in elevated plasma levels, significant variability was observed. A strong correlation (r = 0.992) was found between the administered dose and plasma concentration, though variations in absorption rates and patient demographics likely contributed to the observed variability. This method provides a reliable analytical approach suitable for pharmacokinetic and clinical studies involving metoprolol.

Authors

Institutions

Publication Details

Journal
Separations
Published
2024-10-24
DOI
https://doi.org/10.3390/separations11110306
Primary Topic
Pesticide Residue Analysis and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of Metoprolol Concentrations in Plasma Using Automated Sample Preparation and LC-MS/MS Detection

Valeriu V. Cotea, Mona-Elisabeta Dobrin, B. Nechita, Ionel Bogdan Cioroiu et al.
Separations
Pesticide Residue Analysis and Safety
article

Investigation of Metoprolol Concentrations in Plasma Using Automated Sample Preparation and LC-MS/MS Detection

Valeriu V. Cotea, Mona-Elisabeta Dobrin, B. Nechita, Ionel Bogdan Cioroiu, Marius Niculaua
article en

Abstract

Metoprolol (MTP), a selective beta-1 adrenergic blocker, is commonly administered in the form of succinate or tartrate salts, depending on the pharmaceutical formulation. It is typically prescribed in oral forms as either immediate-release or extended-release tablets. This study describes a chromatographic method using automated sample clean-up and elution via a reversed-phase mechanism. A TurboFlow approach was applied with a Cyclone P column, and the elution was performed isocratically using a mobile phase of water and acetonitrile (0.1% v/v formic acid) within 4.5 min. Quantification of MTP was achieved using triple quadrupole mass spectrometry, with the transition m/z 268.1 → m/z 130.96 for metoprolol, while bisoprolol fumarate, the internal standard, was detected at m/z 326.3 → m/z 116.2. The method was validated according to bioequivalence guidelines. Selectivity was assessed by checking for potential interferences from blank samples or related compounds formed during sample preparation. Precision and accuracy were evaluated both within and between runs, with a maximum coefficient of variation (CV%) of 10.28 and a maximum relative error (ER%) of 5.38. Linearity was demonstrated over the range of 5 ng/L to 1000 ng/L, with a lower limit of quantification at 0.042 ng/L, made possible by injecting larger sample volumes. A matrix effect of 89% was considered acceptable when compared to standard solutions. Plasma concentrations of MTP were monitored in patients administered either 50 mg or 100 mg doses. For the 50 mg dose, plasma levels reached up to 34 μg/L, while the 100 mg dose produced concentrations ranging from 3.56 to 50.81 μg/L. Although the higher dose generally resulted in elevated plasma levels, significant variability was observed. A strong correlation (r = 0.992) was found between the administered dose and plasma concentration, though variations in absorption rates and patient demographics likely contributed to the observed variability. This method provides a reliable analytical approach suitable for pharmacokinetic and clinical studies involving metoprolol.

SeparationsVol. 11(11)
Spitalul Clinic C.F. Iasi (RO), "Ion Ionescu de la Brad" Iasi University of Life Sciences (RO), Romanian Academy (RO)
Openalex Percentile: Top 78%
Pesticide Residue Analysis and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.