EXPERIMENTAL AND MODEL STUDIES OF THE DISTRIBUTED GENERATION INFLUENCE ON THE ASYNCHRONOUS MODES EMERGENCE IN THE INTERCONNECTED POWER SYSTEM OF UKRAINE

The results of experimental and modeling studies of the distributed generation sources (DG) influence on the occur-rence in the Interconnected Power System (IPS) of Ukraine asynchronous modes (AM) caused by accidents in its main electrical network are presented. According to simulation scenarios it was assumed that the DG power was introduced into electrical distribution networks instead of the power units of thermal power plants of the IPS of Ukraine which were destroyed as a result of missile attacks by the Russians. In the absence of information about DGs, certain gener-alizations and assumptions are made regarding the possibility of DG groups modeling of in the form of turbine genera-tors with different inertia constants. Various scenarios of the accidents occurrence and the functioning of relay protec-tion and anti-emergency automation devices were considered. Conducted studies results show that the DG introduction into distribution electrical networks does not contribute to the AM occurrence in the main electrical network of the IPS of Ukraine. References 11, figures 10, tables 3.

Authors

Publication Details

Journal
Tekhnichna Elektrodynamika
Published
2024-10-21
DOI
https://doi.org/10.15407/techned2024.06.067
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EXPERIMENTAL AND MODEL STUDIES OF THE DISTRIBUTED GENERATION INFLUENCE ON THE ASYNCHRONOUS MODES EMERGENCE IN THE INTERCONNECTED POWER SYSTEM OF UKRAINE

A.R. Slobodian, O.F. Butkevych, N.T. Yunieieva, T.M. Hurieieva
Tekhnichna Elektrodynamika
HVDC Systems and Fault Protection
article

EXPERIMENTAL AND MODEL STUDIES OF THE DISTRIBUTED GENERATION INFLUENCE ON THE ASYNCHRONOUS MODES EMERGENCE IN THE INTERCONNECTED POWER SYSTEM OF UKRAINE

A.R. Slobodian, O.F. Butkevych, N.T. Yunieieva, T.M. Hurieieva
article en

Abstract

The results of experimental and modeling studies of the distributed generation sources (DG) influence on the occur-rence in the Interconnected Power System (IPS) of Ukraine asynchronous modes (AM) caused by accidents in its main electrical network are presented. According to simulation scenarios it was assumed that the DG power was introduced into electrical distribution networks instead of the power units of thermal power plants of the IPS of Ukraine which were destroyed as a result of missile attacks by the Russians. In the absence of information about DGs, certain gener-alizations and assumptions are made regarding the possibility of DG groups modeling of in the form of turbine genera-tors with different inertia constants. Various scenarios of the accidents occurrence and the functioning of relay protec-tion and anti-emergency automation devices were considered. Conducted studies results show that the DG introduction into distribution electrical networks does not contribute to the AM occurrence in the main electrical network of the IPS of Ukraine. References 11, figures 10, tables 3.

Tekhnichna ElektrodynamikaVol. 2024(6)
Affordable and clean energy
Openalex Percentile: Top 83%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

EXPERIMENTAL AND MODEL STUDIES OF THE DISTRIBUTED GENERATION INFLUENCE ON THE ASYNCHRONOUS MODES EMERGENCE IN THE INTERCONNECTED POWER SYSTEM OF UKRAINE — A.R. Slobodian, O.F. Butkevych, et al. · Tekhnichna Elektrodynamika (2024) | TGRS Research Map | TGRS