The Role of Host Material in the Design of Ratiometric Optical Density Meters Based on Cr<sup>3+</sup> Luminescence in Y<sub>3</sub>Al<sub>5‐</sub><i><sub>x</sub></i>Ga<i><sub>x</sub></i>O<sub>12</sub>:Cr<sup>3+</sup>

Abstract The skillful combination of luminescent thermometry and optical heating has enabled the development of luminescent optical density meters. However, developing such sensing materials with predefined sensing performance requires an understanding of which material parameters play a dominant role in the optical response of the system. In this study, a systematic investigation is conducted on the influence of host material composition and crystal field strength affecting the Cr 3+ ions on the sensing performance of the ratiometric optical density meter based on the 2 E→ 4 A 2 to 4 T 2 → 4 A 2 luminescence intensity ratio (LIR) in Y 3 Al 5‐ x Ga x O 12 :Cr 3+ . As shown, the LIR reveals thermal variation according to the Boltzmann distribution in these materials over the 160 to 500 K range. However, at higher temperatures, monotonic changes in LIR are still observed. This has enabled the development of optical density meters with high sensitivity, operating over a wide range of power densities (&lt;5500 W cm − 2 ). The maximum sensitivity is found for Y 3 Al 3 Ga 2 O 12 :Cr 3+ , reaching 0.086% W −1 cm 2 at 2 W cm − 2 , which is the highest value reported to date among all ratiometric Cr 3+ ‐based optical density meters. It is demonstrated that a strong crystal field favorably influences the thermal sensitivity of the analyzed systems, thereby achieving high sensitivity in the low optical power density range (&lt;1000 W cm − 2 ). However, it also limits the operating range of the sensing material. Conversely, to extend the operating range of the optical density meter, materials with intermediate or low crystal field strengths are preferred.

Authors

Institutions

Publication Details

Journal
Advanced Optical Materials
Published
2024-10-24
DOI
https://doi.org/10.1002/adom.202402039
Citations
5
Primary Topic
Luminescence Properties of Advanced Materials
Type
article
Field-Weighted Citation Impact
0.59
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Role of Host Material in the Design of Ratiometric Optical Density Meters Based on Cr3+ Luminescence in Y3Al5‐xGaxO12:Cr3+

Justyna Zeler, Ł. Marciniak, Maja Szymczak, Julia Jaśkielewicz
5 citations
Advanced Optical Materials
Luminescence Properties of Advanced Materials
0.59
article

The Role of Host Material in the Design of Ratiometric Optical Density Meters Based on Cr3+ Luminescence in Y3Al5‐xGaxO12:Cr3+

Justyna Zeler, Ł. Marciniak, Maja Szymczak, Julia Jaśkielewicz
article en
5 citations

Abstract

Abstract The skillful combination of luminescent thermometry and optical heating has enabled the development of luminescent optical density meters. However, developing such sensing materials with predefined sensing performance requires an understanding of which material parameters play a dominant role in the optical response of the system. In this study, a systematic investigation is conducted on the influence of host material composition and crystal field strength affecting the Cr 3+ ions on the sensing performance of the ratiometric optical density meter based on the 2 E→ 4 A 2 to 4 T 2 → 4 A 2 luminescence intensity ratio (LIR) in Y 3 Al 5‐ x Ga x O 12 :Cr 3+ . As shown, the LIR reveals thermal variation according to the Boltzmann distribution in these materials over the 160 to 500 K range. However, at higher temperatures, monotonic changes in LIR are still observed. This has enabled the development of optical density meters with high sensitivity, operating over a wide range of power densities (&lt;5500 W cm − 2 ). The maximum sensitivity is found for Y 3 Al 3 Ga 2 O 12 :Cr 3+ , reaching 0.086% W −1 cm 2 at 2 W cm − 2 , which is the highest value reported to date among all ratiometric Cr 3+ ‐based optical density meters. It is demonstrated that a strong crystal field favorably influences the thermal sensitivity of the analyzed systems, thereby achieving high sensitivity in the low optical power density range (&lt;1000 W cm − 2 ). However, it also limits the operating range of the sensing material. Conversely, to extend the operating range of the optical density meter, materials with intermediate or low crystal field strengths are preferred.

Advanced Optical MaterialsVol. 13(2)
University of Wrocław (PL), Polish Academy of Sciences (PL)
Affordable and clean energy
Openalex Percentile: Top 33%
Luminescence Properties of Advanced Materials
0.59
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.