Management of lower extremity venous congestion during peripheral venoarterial extracorporeal membrane oxygenation
During venoarterial extracorporeal membrane oxygenation, right lower extremity congestion occurred due to the insertion of a drain cannula. We effectively managed leg congestion by inserting an additional catheter into the ipsilateral superficial femoral vein.
Authors
- Jonghoon Yoo (ORCID: https://orcid.org/0000-0002-0969-5115)
- Kyungsub Song (ORCID: https://orcid.org/0000-0002-6556-2261)
- Hee Jeong Lee (ORCID: https://orcid.org/0000-0002-0243-6954)
Institutions
- Keimyung University (KR)
Publication Details
- Journal
- Artificial Organs
- Published
- 2024-10-24
- DOI
- https://doi.org/10.1111/aor.14896
- Primary Topic
- Mechanical Circulatory Support Devices
- Type
- article
- Field-Weighted Citation Impact
- 0.00