Real-World Safety of Prostate Cancer Focal Therapy: MAUDE Database Analysis

<b><i>Objective:</i></b> The aim of this study was to assess the real-world safety profile of medical devices used in focal prostate cancer treatment utilizing the Manufacturer and User Facility Device Experience (MAUDE) database. <b><i>Methods:</i></b> The MAUDE database was searched for reports on high-intensity focused ultrasound (HIFU), cryoablation, laser ablation, and irreversible electroporation (IRE) devices used in prostate cancer treatment from 1993 to 2023. Adverse events were identified and categorized. <b><i>Results:</i></b> We identified 175 reports for HIFU, 1362 for cryoablation, 615 for laser ablation, and 135 for IRE devices, with 28, 284, 126, and 2 respective reports, directly related to prostate cancer treatment. The aggregated data revealed the majority of complications were minor, with 82.5% (<i>n</i> = 363 out of 440 total complications) classified as Clavien-Dindo grade 1 or 2. Common minor complications included erectile dysfunction and urinary retention. Severe complications such as rectal fistulas were noted in HIFU and IRE treatments, along with singular mortality due to pulmonary embolism in cryoablation. <b><i>Conclusions:</i></b> Our analyses from MAUDE reveal that devices used in focal therapy for prostate cancer are predominantly associated with minor complications, underscoring their overall real-world safety profile. However, the occurrence of severe adverse events emphasizes the critical importance of rigorous patient selection and meticulous procedural planning. These findings provide valuable insights into the safety profile of focal therapy devices and contribute to the growing body of evidence on their use in prostate cancer treatment.

Authors

Institutions

Publication Details

Journal
Journal of Endourology
Published
2024-10-24
DOI
https://doi.org/10.1089/end.2024.0573
Citations
3
Primary Topic
Prostate Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
1.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-World Safety of Prostate Cancer Focal Therapy: MAUDE Database Analysis

Caroline M. Moore, Zhiyu Qian, Leonardo Oliveira Reis, Julia S. Feldman et al.
3 citations
Journal of Endourology
Prostate Cancer Diagnosis and Treatment
1.26
article

Real-World Safety of Prostate Cancer Focal Therapy: MAUDE Database Analysis

Caroline M. Moore, Zhiyu Qian, Leonardo Oliveira Reis, Julia S. Feldman, Stephan Korn, Daniel Stelzl, Hanna Zurl, Boyuan Xiao, Alexander P. Cole, Filippo Dagnino, J.W. Song, Quoc-Dien Trinh
article en
3 citations

Abstract

<b><i>Objective:</i></b> The aim of this study was to assess the real-world safety profile of medical devices used in focal prostate cancer treatment utilizing the Manufacturer and User Facility Device Experience (MAUDE) database. <b><i>Methods:</i></b> The MAUDE database was searched for reports on high-intensity focused ultrasound (HIFU), cryoablation, laser ablation, and irreversible electroporation (IRE) devices used in prostate cancer treatment from 1993 to 2023. Adverse events were identified and categorized. <b><i>Results:</i></b> We identified 175 reports for HIFU, 1362 for cryoablation, 615 for laser ablation, and 135 for IRE devices, with 28, 284, 126, and 2 respective reports, directly related to prostate cancer treatment. The aggregated data revealed the majority of complications were minor, with 82.5% (<i>n</i> = 363 out of 440 total complications) classified as Clavien-Dindo grade 1 or 2. Common minor complications included erectile dysfunction and urinary retention. Severe complications such as rectal fistulas were noted in HIFU and IRE treatments, along with singular mortality due to pulmonary embolism in cryoablation. <b><i>Conclusions:</i></b> Our analyses from MAUDE reveal that devices used in focal therapy for prostate cancer are predominantly associated with minor complications, underscoring their overall real-world safety profile. However, the occurrence of severe adverse events emphasizes the critical importance of rigorous patient selection and meticulous procedural planning. These findings provide valuable insights into the safety profile of focal therapy devices and contribute to the growing body of evidence on their use in prostate cancer treatment.

Journal of EndourologyVol. 38(12)
Boston University (US), Brigham and Women's Hospital (US), Humanitas University (IT), Universität Hamburg (DE), Medical University of Graz (AT), University Medical Center Hamburg-Eppendorf (DE), University College London (GB), Pontifícia Universidade Católica de Campinas (BR)
Good health and well-being
Openalex Percentile: Top 18%
Prostate Cancer Diagnosis and Treatment
1.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.