Detection of Commutation Failure in LCC-HVDC Transmission System Based on Converter Transformer Valve Side Current

In the line-committed converter-based high voltage direct current (LCC- HVDC) transmission systems, commutation failure (CF) is a prevalent defect, to accurate and reliable detection can provide a basis for system control and protection. The valve side current of the converter transformer, which was easily obtainable in practical engineering, was chosen as the research object to accomplish precise commutation failure detection. The features of this current during commutation failure were researched. Subsequently, a commutation failure discrimination technique was put out, which relied on the converter valve side current's three-phase symmetry and the identical length of each phase's conduction time. A CF detection technique was constructed and tested using a simulation of the CIGRE LCC-HVDC standard testing model. Through simulation, the validity of the theoretical analysis and then the efficacy and precision of the offered CF detection technique were confirmed. This research can provide support in favor of practical engineering.

Authors

Institutions

Publication Details

Published
2024-08-08
DOI
https://doi.org/10.1109/hvdc62448.2024.10722949
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Commutation Failure in LCC-HVDC Transmission System Based on Converter Transformer Valve Side Current

Jietong Liu, Dui Liu, Xiaohua Li
1 citations
HVDC Systems and Fault Protection
0.21
article

Detection of Commutation Failure in LCC-HVDC Transmission System Based on Converter Transformer Valve Side Current

Jietong Liu, Dui Liu, Xiaohua Li
article en
1 citations

Abstract

In the line-committed converter-based high voltage direct current (LCC- HVDC) transmission systems, commutation failure (CF) is a prevalent defect, to accurate and reliable detection can provide a basis for system control and protection. The valve side current of the converter transformer, which was easily obtainable in practical engineering, was chosen as the research object to accomplish precise commutation failure detection. The features of this current during commutation failure were researched. Subsequently, a commutation failure discrimination technique was put out, which relied on the converter valve side current's three-phase symmetry and the identical length of each phase's conduction time. A CF detection technique was constructed and tested using a simulation of the CIGRE LCC-HVDC standard testing model. Through simulation, the validity of the theoretical analysis and then the efficacy and precision of the offered CF detection technique were confirmed. This research can provide support in favor of practical engineering.

Fujian Normal University (CN), South China University of Technology (CN)
Affordable and clean energy
Openalex Percentile: Top 47%
HVDC Systems and Fault Protection
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.