Highlighted Technical Issues Concerning Test Technologies of HV DCCBs

Direct current circuit-breakers (DCCBs) are evolving rapidly. Guide for testing DCCBs is under development where issues relevant to test criteria, testing method and test set-up inspired meaningful discussions. We raise examples of three latest topics in this paper. (1) Reignitions and restrikes in AC CBs can generate over-voltages, threatening other components in the power system but differently, these phenomenon inner a mechanical DCCB has no impact on the system. Nonetheless, they will result in higher peak interrupted current and prolonged current breaking time, which means more energy stress to the MOSAs. (2) MOSAs get in the way of conducting insulation tests because these elements can interfere with the applied test voltages. One way to overcome this obstacle and meanwhile to maintain the voltage shared among components inside the tested DCCB is replacing MOSAs with insulating material. (3) A full-scale test on extra high voltage and above DCCBs requires an extremely large amount of energy which can be practically unfeasible. In such a case, unit test is an alternative based on strict rules.

Authors

Institutions

Publication Details

Published
2024-08-08
DOI
https://doi.org/10.1109/hvdc62448.2024.10722970
Citations
1
Primary Topic
Silicon Carbide Semiconductor Technologies
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highlighted Technical Issues Concerning Test Technologies of HV DCCBs

R.P.P. Smeets, Xiyuan Liao, Shenli Jia, Qiang Tang
1 citations
Silicon Carbide Semiconductor Technologies
0.21
article

Highlighted Technical Issues Concerning Test Technologies of HV DCCBs

R.P.P. Smeets, Xiyuan Liao, Shenli Jia, Qiang Tang
article en
1 citations

Abstract

Direct current circuit-breakers (DCCBs) are evolving rapidly. Guide for testing DCCBs is under development where issues relevant to test criteria, testing method and test set-up inspired meaningful discussions. We raise examples of three latest topics in this paper. (1) Reignitions and restrikes in AC CBs can generate over-voltages, threatening other components in the power system but differently, these phenomenon inner a mechanical DCCB has no impact on the system. Nonetheless, they will result in higher peak interrupted current and prolonged current breaking time, which means more energy stress to the MOSAs. (2) MOSAs get in the way of conducting insulation tests because these elements can interfere with the applied test voltages. One way to overcome this obstacle and meanwhile to maintain the voltage shared among components inside the tested DCCB is replacing MOSAs with insulating material. (3) A full-scale test on extra high voltage and above DCCBs requires an extremely large amount of energy which can be practically unfeasible. In such a case, unit test is an alternative based on strict rules.

Kema International (Netherlands) (NL), Sichuan University (CN), Xi'an Jiaotong University (CN)
Openalex Percentile: Top 47%
Silicon Carbide Semiconductor Technologies
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.