Seismic Vulnerability Analysis of the ±800kV Converter Transformer Before and after Coupling

The transformer-bushing system, a critical component in substations, sustains significant damage during earthquakes. To investigate the response characteristics and seismic vulnerability of transformers during earthquakes, a detailed finite element model of a ±800kV converter transformer was developed. Additionally, a simulation model of the converter transformer coupling system was created based on the actual coupling method. The seismic response time histories of both individual equipment and the coupling system were calculated, and the response characteristics and seismic vulnerability of the equipment were assessed before and after coupling. The results indicate that the first four modes of both the single device and the coupled system are concentrated in the valve-side bushing and the network-side bushing, which are identified as vulnerable points in terms of earthquake resistance. The peak stress response of the coupled system exceeds that of the single device, leading to a higher likelihood of bushing failure under seismic conditions. The coupling negatively impacts the seismic performance of the converter transformer. Various connection methods such as decoupling should be considered to reduce the adverse effects of coupling.

Authors

Institutions

Publication Details

Published
2024-08-08
DOI
https://doi.org/10.1109/hvdc62448.2024.10723080
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seismic Vulnerability Analysis of the ±800kV Converter Transformer Before and after Coupling

Qiang Xie, Rongxing Yu, Jinyun Yu, Qiang Li et al.
Power Systems and Technologies
article

Seismic Vulnerability Analysis of the ±800kV Converter Transformer Before and after Coupling

Qiang Xie, Rongxing Yu, Jinyun Yu, Qiang Li, Weipeng Jiang, Baojun Mao
article en

Abstract

The transformer-bushing system, a critical component in substations, sustains significant damage during earthquakes. To investigate the response characteristics and seismic vulnerability of transformers during earthquakes, a detailed finite element model of a ±800kV converter transformer was developed. Additionally, a simulation model of the converter transformer coupling system was created based on the actual coupling method. The seismic response time histories of both individual equipment and the coupling system were calculated, and the response characteristics and seismic vulnerability of the equipment were assessed before and after coupling. The results indicate that the first four modes of both the single device and the coupled system are concentrated in the valve-side bushing and the network-side bushing, which are identified as vulnerable points in terms of earthquake resistance. The peak stress response of the coupled system exceeds that of the single device, leading to a higher likelihood of bushing failure under seismic conditions. The coupling negatively impacts the seismic performance of the converter transformer. Various connection methods such as decoupling should be considered to reduce the adverse effects of coupling.

Tongji University (CN), China Southern Power Grid (China) (CN)
Climate action
Openalex Percentile: Top 84%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Seismic Vulnerability Analysis of the ±800kV Converter Transformer Before and after Coupling — Qiang Xie, Rongxing Yu, et al. · (2024) | TGRS Research Map | TGRS