Analysis on A Converter Station 750kV AC Filter Circuit Breaker Closing Resistance Fault

AC filter circuit breaker of converter station often uses closing resistance to suppress the closing inrush current generated in the switching process of AC filter. With the repeatedly switching of circuit breaker, because of the high voltage level of 750kV circuit breaker and the large mechanical stress, the closing resistance is easy to get faults, resulting in internal discharge failure of circuit breaker. In this paper, we analysis on a <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm\ 1100\text{KV}$</tex> converter station 750kV AC filter circuit breaker closing resistance fault case. according to the circuit breaker closing fault record waveform analysis, electromagnetic transient simulation inversion, before the circuit breaker failure to analysis the closing resistance fault, through the return to the factory disassembly analysis, verify the correctness of simulation and fault inversion. Successfully avoid a equipment failure trip, and proposed based on AC filter circuit breaker closing waveform monitoring means of circuit breaker closing resistance analysis method, early detection of equipment internal fault state.

Authors

Publication Details

Published
2024-08-08
DOI
https://doi.org/10.1109/hvdc62448.2024.10723063
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis on A Converter Station 750kV AC Filter Circuit Breaker Closing Resistance Fault

Zhijie Ge, Zhaoguang Du, Lei Liu, Fei Zhang et al.
High-Voltage Power Transmission Systems
article

Analysis on A Converter Station 750kV AC Filter Circuit Breaker Closing Resistance Fault

Zhijie Ge, Zhaoguang Du, Lei Liu, Fei Zhang, Longfei Li, Xuefeng Han, Jintao Wen
article en

Abstract

AC filter circuit breaker of converter station often uses closing resistance to suppress the closing inrush current generated in the switching process of AC filter. With the repeatedly switching of circuit breaker, because of the high voltage level of 750kV circuit breaker and the large mechanical stress, the closing resistance is easy to get faults, resulting in internal discharge failure of circuit breaker. In this paper, we analysis on a <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm\ 1100\text{KV}$</tex> converter station 750kV AC filter circuit breaker closing resistance fault case. according to the circuit breaker closing fault record waveform analysis, electromagnetic transient simulation inversion, before the circuit breaker failure to analysis the closing resistance fault, through the return to the factory disassembly analysis, verify the correctness of simulation and fault inversion. Successfully avoid a equipment failure trip, and proposed based on AC filter circuit breaker closing waveform monitoring means of circuit breaker closing resistance analysis method, early detection of equipment internal fault state.

Affordable and clean energy
Openalex Percentile: Top 84%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis on A Converter Station 750kV AC Filter Circuit Breaker Closing Resistance Fault — Zhijie Ge, Zhaoguang Du, et al. · (2024) | TGRS Research Map | TGRS