Influence of Overexcitation Configuration on System Operation Risk of Tianzhong DC Thermal Power Unit

In view of the possible inconsistency between the excitation current value used in the configuration of overexcitation limit and rotor overload protection in the actual system and the excitation current definition in the rotor overcurrent curve in the national standard, the relationship between the excitation AC current and the excitation system DC excitation current was obtained by solving the equation of the rotor control link according to the mathematical model of the rectifier of the excitation system of the unit. Finally, the simulation was carried out for the theoretical part, and the influence of fault types on the action time of the overexcitation limit was compared and analyzed. The final conclusion has guiding significance for the coordination and configuration of overexcitation limit and rotor overload protection in practice.

Authors

Institutions

Publication Details

Published
2024-08-08
DOI
https://doi.org/10.1109/hvdc62448.2024.10722931
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Overexcitation Configuration on System Operation Risk of Tianzhong DC Thermal Power Unit

Bin Feng, Hanchao Ma, Haoliang Gou, Abuduwayiti. Abuduaini et al.
High-Voltage Power Transmission Systems
article

Influence of Overexcitation Configuration on System Operation Risk of Tianzhong DC Thermal Power Unit

Bin Feng, Hanchao Ma, Haoliang Gou, Abuduwayiti. Abuduaini, Jian Wang, Yong Wang
article en

Abstract

In view of the possible inconsistency between the excitation current value used in the configuration of overexcitation limit and rotor overload protection in the actual system and the excitation current definition in the rotor overcurrent curve in the national standard, the relationship between the excitation AC current and the excitation system DC excitation current was obtained by solving the equation of the rotor control link according to the mathematical model of the rectifier of the excitation system of the unit. Finally, the simulation was carried out for the theoretical part, and the influence of fault types on the action time of the overexcitation limit was compared and analyzed. The final conclusion has guiding significance for the coordination and configuration of overexcitation limit and rotor overload protection in practice.

Inner Mongolia Electric Power (China) (CN), Xinjiang Industry Technical College (CN)
Affordable and clean energy
Openalex Percentile: Top 84%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.