Novel Volume Integral Equation Approach for Low-Frequency <i>E</i>-Field Dosimetry of Transcranial Magnetic Stimulation

A new volume integral equation (VIE) approach is introduced to study transcranial magnetic stimulation (TMS) and high-contrast media at low frequencies. This new integral equation offers a simple solution to the high-contrast breakdown observed in low-frequency electric field (E-field) dosimetry of conductive media. Specifically, we employ appropriate approximations that are valid for low frequencies and stabilize the VIE by introducing a basis expansion set that removes solutions associated with high eigenvalues in the equation. The new equation is devoid of high-contrast breakdown and does not require the use of auxiliary surface variables or projectors, providing a straightforward practical solution for the VIE analysis of TMS. Our results indicate that the novel VIE formulation matches boundary element, finite element, and analytical solutions. This new VIE represents a first step towards including anisotropy in integral equation E-field dosimetry for brain stimulation.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Magnetics
Published
2024-10-24
DOI
https://doi.org/10.1109/tmag.2024.3486081
Citations
2
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Volume Integral Equation Approach for Low-Frequency E-Field Dosimetry of Transcranial Magnetic Stimulation

Luis J. Gomez, Seyed Sina Vaezi
2 citations
IEEE Transactions on Magnetics
Advanced MRI Techniques and Applications
0.81
article

Novel Volume Integral Equation Approach for Low-Frequency E-Field Dosimetry of Transcranial Magnetic Stimulation

Luis J. Gomez, Seyed Sina Vaezi
article en
2 citations

Abstract

A new volume integral equation (VIE) approach is introduced to study transcranial magnetic stimulation (TMS) and high-contrast media at low frequencies. This new integral equation offers a simple solution to the high-contrast breakdown observed in low-frequency electric field (E-field) dosimetry of conductive media. Specifically, we employ appropriate approximations that are valid for low frequencies and stabilize the VIE by introducing a basis expansion set that removes solutions associated with high eigenvalues in the equation. The new equation is devoid of high-contrast breakdown and does not require the use of auxiliary surface variables or projectors, providing a straightforward practical solution for the VIE analysis of TMS. Our results indicate that the novel VIE formulation matches boundary element, finite element, and analytical solutions. This new VIE represents a first step towards including anisotropy in integral equation E-field dosimetry for brain stimulation.

IEEE Transactions on MagneticsVol. 60(12)
Purdue University West Lafayette (US)
National Institutes of Health, National Institute of Mental Health
Openalex Percentile: Top 25%
Advanced MRI Techniques and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.