Typical Fault Analysis of SF6 Gas Insulated Metal Enclosed Circuit Breaker Compartment

An analysis is conducted on typical faults in the circuit breaker compartment of a 750 kV Gas Insulated Switchgear (GIS) at a substation, proposing an analytical method and process applicable to fault situations in the circuit breaker compartment of 750 kV GIS equipment. Firstly, the fault chamber is located using infrared temperature measurement and SF6 gas decomposition product analysis. Subsequently, the observation hole cover is opened on-site to conduct preliminary analysis of the fault cause. Next, the faulty chamber's components are dismantled and inspected at the factory, employing test methods such as metal composition analysis and phase analysis to confirm the cause of the fault and further analyze the accident's cause. Finally, based on the internal conditions of the faulty chamber and test results, the accurate cause is determined, providing effective reference for the operation and maintenance of the circuit breaker compartment.

Authors

Institutions

Publication Details

Published
2024-08-08
DOI
https://doi.org/10.1109/hvdc62448.2024.10723077
Primary Topic
Power Line Inspection Robots
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Typical Fault Analysis of SF6 Gas Insulated Metal Enclosed Circuit Breaker Compartment

Niyaer Di, Huimin Guo, Jinxin Wang, Longxiang Yuang
Power Line Inspection Robots
article

Typical Fault Analysis of SF6 Gas Insulated Metal Enclosed Circuit Breaker Compartment

Niyaer Di, Huimin Guo, Jinxin Wang, Longxiang Yuang
article en

Abstract

An analysis is conducted on typical faults in the circuit breaker compartment of a 750 kV Gas Insulated Switchgear (GIS) at a substation, proposing an analytical method and process applicable to fault situations in the circuit breaker compartment of 750 kV GIS equipment. Firstly, the fault chamber is located using infrared temperature measurement and SF6 gas decomposition product analysis. Subsequently, the observation hole cover is opened on-site to conduct preliminary analysis of the fault cause. Next, the faulty chamber's components are dismantled and inspected at the factory, employing test methods such as metal composition analysis and phase analysis to confirm the cause of the fault and further analyze the accident's cause. Finally, based on the internal conditions of the faulty chamber and test results, the accurate cause is determined, providing effective reference for the operation and maintenance of the circuit breaker compartment.

Inner Mongolia Electric Power (China) (CN)
Sustainable cities and communities
Openalex Percentile: Top 81%
Power Line Inspection Robots
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Typical Fault Analysis of SF6 Gas Insulated Metal Enclosed Circuit Breaker Compartment — Niyaer Di, Huimin Guo, et al. · (2024) | TGRS Research Map | TGRS