Design and Analysis of Rectangular Microcantilever based Sensor with Stress Concentration Region for Biomolecule Detection

Many life-threatening diseases are diagnosed at advanced, critical stages due to clinical limitations. Early detection through monitoring patient health metrics and identifying disease-causing antigens and their concentrations is crucial for timely medical intervention. To address this, highly sensitive and reliable methods for antigen detection are needed. Biosensors offer a promising solution for accurately classifying and detecting biomolecules. The emergence of new viruses and disease causing antigens highlights the importance of active healthcare measures. High-performance biosensors and its signal conditioning circuits are important for safeguarding human health. This paper focuses on a MEMS-based microcantilever biosensor, its transduction principle for biomolecule detection, simulation of rectangular microcantilever for biomolecule equivalent of 19 Pascal. It has been identified by introducing stress concentration region (SCR), the sensitivity of the sensor is increased and it has maximum displacement in trapezoidal SCR in the rectangular microcantilever and shows 40% improvement than the conventional rectangular microcantilever.

Authors

Institutions

Publication Details

Published
2024-09-18
DOI
https://doi.org/10.1109/icosec61587.2024.10722299
Primary Topic
Mechanical and Optical Resonators
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Analysis of Rectangular Microcantilever based Sensor with Stress Concentration Region for Biomolecule Detection

V. R. Anitha, M. Lakshmi Prasanna
Mechanical and Optical Resonators
article

Design and Analysis of Rectangular Microcantilever based Sensor with Stress Concentration Region for Biomolecule Detection

V. R. Anitha, M. Lakshmi Prasanna
article en

Abstract

Many life-threatening diseases are diagnosed at advanced, critical stages due to clinical limitations. Early detection through monitoring patient health metrics and identifying disease-causing antigens and their concentrations is crucial for timely medical intervention. To address this, highly sensitive and reliable methods for antigen detection are needed. Biosensors offer a promising solution for accurately classifying and detecting biomolecules. The emergence of new viruses and disease causing antigens highlights the importance of active healthcare measures. High-performance biosensors and its signal conditioning circuits are important for safeguarding human health. This paper focuses on a MEMS-based microcantilever biosensor, its transduction principle for biomolecule detection, simulation of rectangular microcantilever for biomolecule equivalent of 19 Pascal. It has been identified by introducing stress concentration region (SCR), the sensitivity of the sensor is increased and it has maximum displacement in trapezoidal SCR in the rectangular microcantilever and shows 40% improvement than the conventional rectangular microcantilever.

International Institute of Information Technology Bangalore (IN), Jawaharlal Nehru Technological University Anantapur (IN)
Openalex Percentile: Top 83%
Mechanical and Optical Resonators
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and Analysis of Rectangular Microcantilever based Sensor with Stress Concentration Region for Biomolecule Detection — V. R. Anitha, M. Lakshmi Prasanna · (2024) | TGRS Research Map | TGRS