Improved Low Concentration Water Content Detection in Biodiesel Utilizing Phase-Shift-Based Capacitive Method

Biodiesel has become an alternative fuel to substitute conventional fuel, yet challenges remain, particularly concerning water content. The presence of water in biodiesel can negatively impact engine spray and combustion properties and may lead to damage storage tanks. To address this issue, a phase-shift-based capacitive sensor was developed in this study to accurately measure water concentration in biodiesel. The sensor, designed with a semicylindrical electrode on a glass tube, is integrated with a signal conditioning circuit and the Digilent Analog Discovery module, allowing for real-time data analysis and enhanced sensitivity in detecting low concentrations of water concentration in biodiesel. The experimental results demonstrated a direct correlation between capacitance values and phase shift, with higher capacitance leading to more significant phase shifts. A Bode plot and simulation analysis, utilizing the transfer function, validated these experimental conditions, confirming the relationship between capacitance and signal phase shift. Additionally, experiments assessing biodiesel water content revealed a proportional increase in phase-shift angle with rising water concentration, measuring water concentration in biodiesel at levels as low as 800 ppm. These findings underscore that the phase-shift magnitude in the sensor’s output reliably detects low-concentration water content in biodiesel. The performance of this sensor is particularly advantageous due to its high sensitivity, enabling the detection of low water concentrations that are crucial for maintaining biodiesel quality. Moreover, the real-time data analysis capability provided by the Digilent Analog Discovery highlights the sensor’s practicality and efficiency for on-the-spot monitoring, offering a significant improvement over conventional methods.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2024-10-24
DOI
https://doi.org/10.1109/jsen.2024.3483290
Citations
1
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improved Low Concentration Water Content Detection in Biodiesel Utilizing Phase-Shift-Based Capacitive Method

TK Berkah Fajar, Ratno Nuryadi, Fatih Dzulfiqar, Nacep Suryana et al.
1 citations
IEEE Sensors Journal
Spectroscopy and Chemometric Analyses
0.24
article

Improved Low Concentration Water Content Detection in Biodiesel Utilizing Phase-Shift-Based Capacitive Method

TK Berkah Fajar, Ratno Nuryadi, Fatih Dzulfiqar, Nacep Suryana, Hari Sumartono, Achmad Widodo, Illyas Md Isa, Mahfudz Al Huda, Suriani Abu Bakar, Azmi Muhamed
article en
1 citations

Abstract

Biodiesel has become an alternative fuel to substitute conventional fuel, yet challenges remain, particularly concerning water content. The presence of water in biodiesel can negatively impact engine spray and combustion properties and may lead to damage storage tanks. To address this issue, a phase-shift-based capacitive sensor was developed in this study to accurately measure water concentration in biodiesel. The sensor, designed with a semicylindrical electrode on a glass tube, is integrated with a signal conditioning circuit and the Digilent Analog Discovery module, allowing for real-time data analysis and enhanced sensitivity in detecting low concentrations of water concentration in biodiesel. The experimental results demonstrated a direct correlation between capacitance values and phase shift, with higher capacitance leading to more significant phase shifts. A Bode plot and simulation analysis, utilizing the transfer function, validated these experimental conditions, confirming the relationship between capacitance and signal phase shift. Additionally, experiments assessing biodiesel water content revealed a proportional increase in phase-shift angle with rising water concentration, measuring water concentration in biodiesel at levels as low as 800 ppm. These findings underscore that the phase-shift magnitude in the sensor’s output reliably detects low-concentration water content in biodiesel. The performance of this sensor is particularly advantageous due to its high sensitivity, enabling the detection of low water concentrations that are crucial for maintaining biodiesel quality. Moreover, the real-time data analysis capability provided by the Digilent Analog Discovery highlights the sensor’s practicality and efficiency for on-the-spot monitoring, offering a significant improvement over conventional methods.

IEEE Sensors JournalVol. 24(24)
Diponegoro University (ID), Sultan Idris Education University (MY), University of Indonesia (ID), National Nuclear Energy Agency of Indonesia (ID), National Research and Innovation Agency (ID)
Clean water and sanitation
Openalex Percentile: Top 50%
Spectroscopy and Chemometric Analyses
0.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.