A Fast and Setting-Less Breaker Failure Backup Protection Scheme for Multi-Terminal HVDC Grids

Breaker failure backup protection schemes are essential for the reliable operation of high voltage direct current (HVDC) grids and to prevent damages to power system equipment due to sustained faults. This paper proposes a rapid, reliable, and setting-less breaker failure backup protection scheme for multi-terminal HVDC grids. The proposed scheme employs Hilbert-Huang Transform (HHT) to extract two features from local voltage measurements, namely the instantaneous frequency and energy. Based on detected outliers in the extracted instantaneous features, breaker failure events are rapidly detected. The proposed setting-less outlier-based criterion can be applied to HVDC grids with various configurations, parameters, and breaker technologies. The proposed scheme depends only on local voltage measurements to detect breaker failure events within <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\text{1} \, \text{ms} $</tex-math></inline-formula> from the intended breaker trip time without requiring breaker voltage or current measurements. In addition, the proposed scheme can successfully detect breaker failure events during high-resistance faults (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$1500 \, \Omega$</tex-math></inline-formula>) and in grids with small boundary reactors (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\text{10} \, \text{mH} $</tex-math></inline-formula>). Numerous simulations in PSCAD/EMTDC software environment for a four-terminal HVDC grid are executed to demonstrate the rapid and reliable performance of the proposed breaker failure backup protection scheme under severe fault conditions.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2024-10-24
DOI
https://doi.org/10.1109/tpwrd.2024.3486290
Citations
1
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fast and Setting-Less Breaker Failure Backup Protection Scheme for Multi-Terminal HVDC Grids

Mohamed Radwan, Sahar Pirooz Azad
1 citations
IEEE Transactions on Power Delivery
HVDC Systems and Fault Protection
0.21
article

A Fast and Setting-Less Breaker Failure Backup Protection Scheme for Multi-Terminal HVDC Grids

Mohamed Radwan, Sahar Pirooz Azad
article en
1 citations

Abstract

Breaker failure backup protection schemes are essential for the reliable operation of high voltage direct current (HVDC) grids and to prevent damages to power system equipment due to sustained faults. This paper proposes a rapid, reliable, and setting-less breaker failure backup protection scheme for multi-terminal HVDC grids. The proposed scheme employs Hilbert-Huang Transform (HHT) to extract two features from local voltage measurements, namely the instantaneous frequency and energy. Based on detected outliers in the extracted instantaneous features, breaker failure events are rapidly detected. The proposed setting-less outlier-based criterion can be applied to HVDC grids with various configurations, parameters, and breaker technologies. The proposed scheme depends only on local voltage measurements to detect breaker failure events within <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\text{1} \, \text{ms} $</tex-math></inline-formula> from the intended breaker trip time without requiring breaker voltage or current measurements. In addition, the proposed scheme can successfully detect breaker failure events during high-resistance faults (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$1500 \, \Omega$</tex-math></inline-formula>) and in grids with small boundary reactors (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\text{10} \, \text{mH} $</tex-math></inline-formula>). Numerous simulations in PSCAD/EMTDC software environment for a four-terminal HVDC grid are executed to demonstrate the rapid and reliable performance of the proposed breaker failure backup protection scheme under severe fault conditions.

IEEE Transactions on Power DeliveryVol. 39(6)
University of Waterloo (CA)
Natural Sciences and Engineering Research Council of Canada
Climate action
Openalex Percentile: Top 47%
HVDC Systems and Fault Protection
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.