Current-Limiting Control Strategy for Indirect-Current-Controlled Active Power Filter

Indirect-current-controlled active power filter (APF) is preferable compared with the direct-current-controlled APF due to its simpler structure and its direct regulation of the grid current. However, unlike direct current control, indirect current control does not have explicit current reference posing difficulty on current limiting operation. This letter proposes a current-limiting control strategy for indirect-current-controlled APF. By adding harmonic resonant controllers into the closed-loop control of the APF's output current, the harmonic components of output current can be smaller than that of the nonlinear load's current. The effectiveness of the proposed current-limiting control is verified by experiments.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2024-10-24
DOI
https://doi.org/10.1109/tpwrd.2024.3485950
Citations
4
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Current-Limiting Control Strategy for Indirect-Current-Controlled Active Power Filter

Shan He, Ka Nang Leung, Poh Chiang Loh, Chao Gao et al.
4 citations
IEEE Transactions on Power Delivery
Power Quality and Harmonics
0.83
article

Current-Limiting Control Strategy for Indirect-Current-Controlled Active Power Filter

Shan He, Ka Nang Leung, Poh Chiang Loh, Chao Gao, Xiongfeng Fang, Frede Blaabjerg, Pooya Davari
article en
4 citations

Abstract

Indirect-current-controlled active power filter (APF) is preferable compared with the direct-current-controlled APF due to its simpler structure and its direct regulation of the grid current. However, unlike direct current control, indirect current control does not have explicit current reference posing difficulty on current limiting operation. This letter proposes a current-limiting control strategy for indirect-current-controlled APF. By adding harmonic resonant controllers into the closed-loop control of the APF's output current, the harmonic components of output current can be smaller than that of the nonlinear load's current. The effectiveness of the proposed current-limiting control is verified by experiments.

IEEE Transactions on Power DeliveryVol. 39(6)
Chinese University of Hong Kong (HK), Nanjing University of Science and Technology (CN), Aalborg University (DK)
Affordable and clean energy
Openalex Percentile: Top 26%
Power Quality and Harmonics
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.