The Feasibility of an Experimental Hypobaric Simulation to Evaluate the Safety of Closed-Loop Insulin Delivery Systems in Flight-Related Atmospheric Pressure Changes

Hybrid closed-loop (HCL) systems remain underexplored within aviation, and as atmospheric pressure changes can independently affect insulin pumps and continuous glucose monitoring readings, this preliminary study assessed the feasibility of HCL safety evaluation, in both fasting and post-prandial states, by using hypobaric chamber to simulate flights. Participants with type 1 diabetes and on HCL were studied: Medtronic Guardian 4-Medtronic 780G-SmartGuard (<i>n</i> = 4), Dexcom G6-Omnipod DASH-Android APS (<i>n</i> = 1), and Dexcom G6-Ypsomed Pump-CamAPS (<i>n</i> = 1). Flight cabin pressures of 550 mmHg and 750 mmHg were simulated in a hypobaric chamber. Seven-hundred-50 glucose measurements were taken, with glucose levels demonstrating a stable decline to 4 mmol/L during fasting. To maintain a tight fasting and post-prandial glucose range across the different pressure settings, the HCL administered insulin as expected. While not demonstrating any apparent issues, repeating flight simulation protocol with other systems, examining longer flights, and undertaking larger, powered randomised controlled trials can confirm their safety in aviation.

Authors

Institutions

Publication Details

Journal
Diabetes Technology & Therapeutics
Published
2024-10-24
DOI
https://doi.org/10.1089/dia.2024.0380
Citations
7
Primary Topic
Diabetes Management and Research
Type
article
Field-Weighted Citation Impact
2.50
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Feasibility of an Experimental Hypobaric Simulation to Evaluate the Safety of Closed-Loop Insulin Delivery Systems in Flight-Related Atmospheric Pressure Changes

Petra Baumann, Ka Siu Fan, Julia Katharina Mader, Victoria Edwards et al.
7 citations
Diabetes Technology & Therapeutics
Diabetes Management and Research
2.50
article

The Feasibility of an Experimental Hypobaric Simulation to Evaluate the Safety of Closed-Loop Insulin Delivery Systems in Flight-Related Atmospheric Pressure Changes

Petra Baumann, Ka Siu Fan, Julia Katharina Mader, Victoria Edwards, Gerd Koehler, Vivienne Lee, David Russell‐Jones, Fariba Shojaee‐Moradie, Chantal Mathieu, Antonios Manoli
article en
7 citations

Abstract

Hybrid closed-loop (HCL) systems remain underexplored within aviation, and as atmospheric pressure changes can independently affect insulin pumps and continuous glucose monitoring readings, this preliminary study assessed the feasibility of HCL safety evaluation, in both fasting and post-prandial states, by using hypobaric chamber to simulate flights. Participants with type 1 diabetes and on HCL were studied: Medtronic Guardian 4-Medtronic 780G-SmartGuard (<i>n</i> = 4), Dexcom G6-Omnipod DASH-Android APS (<i>n</i> = 1), and Dexcom G6-Ypsomed Pump-CamAPS (<i>n</i> = 1). Flight cabin pressures of 550 mmHg and 750 mmHg were simulated in a hypobaric chamber. Seven-hundred-50 glucose measurements were taken, with glucose levels demonstrating a stable decline to 4 mmol/L during fasting. To maintain a tight fasting and post-prandial glucose range across the different pressure settings, the HCL administered insulin as expected. While not demonstrating any apparent issues, repeating flight simulation protocol with other systems, examining longer flights, and undertaking larger, powered randomised controlled trials can confirm their safety in aviation.

Diabetes Technology & TherapeuticsVol. 27(2)
Qinetiq (United Kingdom) (GB), Medical University of Graz (AT), Civil Aviation Authority (GB), Royal Surrey County Hospital (GB), University of Surrey (GB), VIB-KU Leuven Center for Microbiology (BE), KU Leuven (BE)
Climate action
Openalex Percentile: Top 9%
Diabetes Management and Research
2.50
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.