A framework to model charge sharing and pulse pileup for virtual imaging trials of photon-counting CT

<i>Objective.</i>This study describes the development, validation, and integration of a detector response model that accounts for the combined effects of x-ray crosstalk, charge sharing, and pulse pileup in photon-counting detectors.<i>Approach.</i>The x-ray photon transport was simulated using Geant4, followed by analytical charge sharing simulation in MATLAB. The analytical simulation models charge clouds with Gaussian-distributed charge densities, which are projected on a 3×3 pixel neighborhood of interaction location to compute detected counts. For pulse pileup, a prior analytical method for redistribution of energy-binned counts was implemented for delta pulses. The x-ray photon transport and charge sharing components were validated using experimental data acquired on the CdTe-based Pixirad-1/Pixie-III detector using monoenergetic beams at 26, 33, 37, and 50 keV. The pulse pileup implementation was verified with a comparable Monte Carlo simulation. The model output without pulse pileup was used to generate spatio-energetic response matrices for efficient simulation of scanner-specific photon-counting CT (PCCT) images with DukeSim, with pulse pileup modeled as a post-processing step on simulated projections. For analysis, images for the Gammex multi-energy phantom and the XCAT chest phantom were simulated at 120 kV, both with and without pulse pileup for a range of doses (27-1344 mAs). The XCAT images were evaluated qualitatively at 120 mAs, while images for the Gammex phantom were evaluated quantitatively for all doses using measurements of attenuation coefficients and Calcium concentrations.<i>Main results.</i>Reasonable agreement was observed between simulated and experimental spectra with Mean Absolute Percentage Error Values (MAPE) between 10%and 31%across all incident energies and detector modes. The increased pulse pileup from increased dose affected attenuation coefficients and calcium concentrations, with an effect on calcium quantification as high as MAPE of 28%.<i>Significance.</i>The presented approach demonstrates the viability of the model for enabling VITs to assess and optimize the clinical performance of PCCT.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-10-24
DOI
https://doi.org/10.1088/1361-6560/ad8b0a
Citations
4
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A framework to model charge sharing and pulse pileup for virtual imaging trials of photon-counting CT

Stevan Vrbaški, Ehsan Samei, Renata Longo, Mridul Bhattarai et al.
4 citations
Physics in Medicine and Biology
Advanced X-ray and CT Imaging
0.74
article

A framework to model charge sharing and pulse pileup for virtual imaging trials of photon-counting CT

Stevan Vrbaški, Ehsan Samei, Renata Longo, Mridul Bhattarai, Ehsan Abadi, Shobhit Sharma
article en
4 citations

Abstract

<i>Objective.</i>This study describes the development, validation, and integration of a detector response model that accounts for the combined effects of x-ray crosstalk, charge sharing, and pulse pileup in photon-counting detectors.<i>Approach.</i>The x-ray photon transport was simulated using Geant4, followed by analytical charge sharing simulation in MATLAB. The analytical simulation models charge clouds with Gaussian-distributed charge densities, which are projected on a 3×3 pixel neighborhood of interaction location to compute detected counts. For pulse pileup, a prior analytical method for redistribution of energy-binned counts was implemented for delta pulses. The x-ray photon transport and charge sharing components were validated using experimental data acquired on the CdTe-based Pixirad-1/Pixie-III detector using monoenergetic beams at 26, 33, 37, and 50 keV. The pulse pileup implementation was verified with a comparable Monte Carlo simulation. The model output without pulse pileup was used to generate spatio-energetic response matrices for efficient simulation of scanner-specific photon-counting CT (PCCT) images with DukeSim, with pulse pileup modeled as a post-processing step on simulated projections. For analysis, images for the Gammex multi-energy phantom and the XCAT chest phantom were simulated at 120 kV, both with and without pulse pileup for a range of doses (27-1344 mAs). The XCAT images were evaluated qualitatively at 120 mAs, while images for the Gammex phantom were evaluated quantitatively for all doses using measurements of attenuation coefficients and Calcium concentrations.<i>Main results.</i>Reasonable agreement was observed between simulated and experimental spectra with Mean Absolute Percentage Error Values (MAPE) between 10%and 31%across all incident energies and detector modes. The increased pulse pileup from increased dose affected attenuation coefficients and calcium concentrations, with an effect on calcium quantification as high as MAPE of 28%.<i>Significance.</i>The presented approach demonstrates the viability of the model for enabling VITs to assess and optimize the clinical performance of PCCT.

Physics in Medicine and BiologyVol. 69(22)
University of Trieste (IT), University of Novi Sad (RS), Duke University (US), Elettra-Sincrotrone Trieste S.C.p.A. (IT), Duke Medical Center (US), Advanced Imaging Research (United States) (US), Istituto Nazionale di Fisica Nucleare, Sezione di Trieste (IT)
Foundation for the National Institutes of Health, Johns Hopkins University, Siemens Healthineers, National Institutes of Health
Affordable and clean energy
Openalex Percentile: Top 32%
Advanced X-ray and CT Imaging
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.