ALTP heat flux sensor: the compensation of the ordinary Seebeck effect through a new structure

Abstract This technical note highlights the detrimental impact of the ordinary Seebeck effect (SE) on the accuracy of atomic layer thermopile (ALTP) heat flux sensors and presents an innovative structural design and correction approach. ALTP sensors are based on the Transverse Seebeck effect (TSE), linking their output directly to the temperature difference (Δ T z ) across the sensor’s sensitive film layers. Experimental analysis reveals that a temperature gradient (Δ T x ) along the film’s tilt direction, via the SE, introduces a bias voltage, causing a substantial maximum relative error of 56.4% in measurements. To counteract this issue, we introduce a novel structural configuration and correction strategy, effectively reducing the relative error to 4.1%, and thereby significantly enhancing the precision of ALTP heat flux sensors.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2024-10-24
DOI
https://doi.org/10.1088/1361-6501/ad8ae0
Citations
1
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ALTP heat flux sensor: the compensation of the ordinary Seebeck effect through a new structure

Tian Xie, Bowan Tao, Xi Chen, Ruipeng Zhao et al.
1 citations
Measurement Science and Technology
Advanced Sensor Technologies Research
0.18
article

ALTP heat flux sensor: the compensation of the ordinary Seebeck effect through a new structure

Tian Xie, Bowan Tao, Xi Chen, Ruipeng Zhao, Meng Zhao, Zhenzhe Li, Kai Yang
article en
1 citations

Abstract

Abstract This technical note highlights the detrimental impact of the ordinary Seebeck effect (SE) on the accuracy of atomic layer thermopile (ALTP) heat flux sensors and presents an innovative structural design and correction approach. ALTP sensors are based on the Transverse Seebeck effect (TSE), linking their output directly to the temperature difference (Δ T z ) across the sensor’s sensitive film layers. Experimental analysis reveals that a temperature gradient (Δ T x ) along the film’s tilt direction, via the SE, introduces a bias voltage, causing a substantial maximum relative error of 56.4% in measurements. To counteract this issue, we introduce a novel structural configuration and correction strategy, effectively reducing the relative error to 4.1%, and thereby significantly enhancing the precision of ALTP heat flux sensors.

Measurement Science and TechnologyVol. 36(1)
University of Electronic Science and Technology of China (CN), China Aerodynamics Research and Development Center (CN), National Engineering Research Center of Electromagnetic Radiation Control Materials (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 51%
Advanced Sensor Technologies Research
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ALTP heat flux sensor: the compensation of the ordinary Seebeck effect through a new structure — Tian Xie, Bowan Tao, et al. · Measurement Science and Technology (2024) | TGRS Research Map | TGRS