A Novel Gold Nanoparticle‐Ionic Liquid Nanostructure Modified <i>Pleurotus Ostreatus</i> Based Microbial Biosensor System For Bisphenol A

Abstract The current study develops the first and novel gold nanoparticle‐ionic liquid nanostructure modified microbial biosensor based on Pleurotus ostreatus for the sensitive determination of Bisphenol A. In the construction of the microbial biosensor, lyophilized P.ostreatus cells were modified with ionic liquid‐cysteamine mixture on a gold electrode which was modified with 1,6‐hexanedithiol and gold nanoparticle. The measurement principle of the biosensor is based on the detection of changes in current in a phosphate buffer system (pH 7.5, 50 mM and containing 5.0 mM K 3 [Fe(CN) 6 ]) in the potential range of −0.2 to +0.6 V depending on the BPA concentration. In the optimization studies of the microbial biosensor; the most suitable ionic liquid‐cysteamin ratio was 1 : 2 (v/v) and the incubation time of 1,6‐hexanedithiol on the gold electrode was 6 hours. Optimum working conditions were determined to be pH:7.5, 100 mM potassium phosphate buffer, and 35°C. In the characterization studies of the microbial biosensor, parameters such as linearity, interference effects of some substances on the microbial biosensor responses, repeatability, reproducibility and storage stability of the microbial biosensor were determined. The linear range of the biosensor was obtained 10–250 μM. Limit of detection was determined to be 1.57 μM and the response time was obtained 20 seconds. Real sample analysis was carried out by water samples that kept in plastic bottles for 6 months by using both the microbial biosensor and HPLC method.

Authors

Institutions

Publication Details

Journal
Electroanalysis
Published
2024-10-24
DOI
https://doi.org/10.1002/elan.202400290
Citations
2
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Gold Nanoparticle‐Ionic Liquid Nanostructure Modified Pleurotus Ostreatus Based Microbial Biosensor System For Bisphenol A

Erol Akyılmaz, M. Emın Günay, Hayati Türkmen, I Wayan Putu Sutirta Yasa et al.
2 citations
Electroanalysis
Electrochemical sensors and biosensors
0.42
article

A Novel Gold Nanoparticle‐Ionic Liquid Nanostructure Modified Pleurotus Ostreatus Based Microbial Biosensor System For Bisphenol A

Erol Akyılmaz, M. Emın Günay, Hayati Türkmen, I Wayan Putu Sutirta Yasa, E. Öztürk
article en
2 citations

Abstract

Abstract The current study develops the first and novel gold nanoparticle‐ionic liquid nanostructure modified microbial biosensor based on Pleurotus ostreatus for the sensitive determination of Bisphenol A. In the construction of the microbial biosensor, lyophilized P.ostreatus cells were modified with ionic liquid‐cysteamine mixture on a gold electrode which was modified with 1,6‐hexanedithiol and gold nanoparticle. The measurement principle of the biosensor is based on the detection of changes in current in a phosphate buffer system (pH 7.5, 50 mM and containing 5.0 mM K 3 [Fe(CN) 6 ]) in the potential range of −0.2 to +0.6 V depending on the BPA concentration. In the optimization studies of the microbial biosensor; the most suitable ionic liquid‐cysteamin ratio was 1 : 2 (v/v) and the incubation time of 1,6‐hexanedithiol on the gold electrode was 6 hours. Optimum working conditions were determined to be pH:7.5, 100 mM potassium phosphate buffer, and 35°C. In the characterization studies of the microbial biosensor, parameters such as linearity, interference effects of some substances on the microbial biosensor responses, repeatability, reproducibility and storage stability of the microbial biosensor were determined. The linear range of the biosensor was obtained 10–250 μM. Limit of detection was determined to be 1.57 μM and the response time was obtained 20 seconds. Real sample analysis was carried out by water samples that kept in plastic bottles for 6 months by using both the microbial biosensor and HPLC method.

ElectroanalysisVol. 37(1)
Ege University (TR), Adnan Menderes University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Openalex Percentile: Top 37%
Electrochemical sensors and biosensors
0.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.