Stimulated echo acquisition mode (STEAM) diffusion tensor imaging with different diffusion encoding times in the supraspinatus muscle: Test–retest reliability and comparison to spin echo diffusion tensor imaging

Diffusion tensor imaging (DTI) provides insight into the skeletal muscle microstructure and can be acquired using a stimulated echo acquisition mode (STEAM)-based approach to quantify time-dependent tissue diffusion. This study examined diffusion metrics and signal-to-noise ratio (SNR) in the supraspinatus muscle obtained with a STEAM-DTI sequence with different diffusion encoding times (Δ) and compared them to measures from a spin echo (SE) sequence. Ten healthy subjects (mean age 31.5 ± 4.7 years; five females) underwent 3-Tesla STEAM and SE-DTI of the shoulder in three sessions. STEAM was acquired with Δ of 100/200/400/600 ms. The diffusion encoding time in SE scans was 19 ms (b = 500 s/mm<sup>2</sup>). Region of interest-based measurement of fractional anisotropy (FA), mean diffusivity (MD), and SNR was performed. Intraclass correlation coefficients (ICCs) were computed to assess test-retest reliability. ANOVA with post-hoc pairwise tests was used to compare measures between different Δ of STEAM as well as STEAM and SE, respectively. FA was significantly higher (FA<sub>STEAM</sub>: 0.38-0.46 vs. FA<sub>SE</sub>: 0.26) and MD significantly lower (MD<sub>STEAM</sub>: 1.20-1.33 vs. MD<sub>SE</sub>: 1.62 × 10<sup>-3</sup> mm<sup>2</sup>/s) in STEAM compared to SE (p < 0.001, respectively). SNR was significantly higher for SE (72.3 ± 8.7) than for STEAM (p < 0.001). ICCs were excellent for FA in STEAM (≥0.911) and SE (0.960). For MD, ICCs were good for STEAM<sub>100ms-600ms</sub> (≥0.759) and SE (0.752). STEAM and SE exhibited excellent reliability for FA and good reliability for MD in the supraspinatus muscle. SNR was significantly higher in SE compared to STEAM.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2024-10-24
DOI
https://doi.org/10.1002/nbm.5279
Citations
2
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stimulated echo acquisition mode (STEAM) diffusion tensor imaging with different diffusion encoding times in the supraspinatus muscle: Test–retest reliability and comparison to spin echo diffusion tensor imaging

Constantin von Deuster, Daniel Nanz, Thorsten Feiweier, Reto Sutter et al.
2 citations
NMR in Biomedicine
Advanced Neuroimaging Techniques and Applications
0.81
article

Stimulated echo acquisition mode (STEAM) diffusion tensor imaging with different diffusion encoding times in the supraspinatus muscle: Test–retest reliability and comparison to spin echo diffusion tensor imaging

Constantin von Deuster, Daniel Nanz, Thorsten Feiweier, Reto Sutter, Stefan Sommer, Adrian A. Marth
article en
2 citations

Abstract

Diffusion tensor imaging (DTI) provides insight into the skeletal muscle microstructure and can be acquired using a stimulated echo acquisition mode (STEAM)-based approach to quantify time-dependent tissue diffusion. This study examined diffusion metrics and signal-to-noise ratio (SNR) in the supraspinatus muscle obtained with a STEAM-DTI sequence with different diffusion encoding times (Δ) and compared them to measures from a spin echo (SE) sequence. Ten healthy subjects (mean age 31.5 ± 4.7 years; five females) underwent 3-Tesla STEAM and SE-DTI of the shoulder in three sessions. STEAM was acquired with Δ of 100/200/400/600 ms. The diffusion encoding time in SE scans was 19 ms (b = 500 s/mm<sup>2</sup>). Region of interest-based measurement of fractional anisotropy (FA), mean diffusivity (MD), and SNR was performed. Intraclass correlation coefficients (ICCs) were computed to assess test-retest reliability. ANOVA with post-hoc pairwise tests was used to compare measures between different Δ of STEAM as well as STEAM and SE, respectively. FA was significantly higher (FA<sub>STEAM</sub>: 0.38-0.46 vs. FA<sub>SE</sub>: 0.26) and MD significantly lower (MD<sub>STEAM</sub>: 1.20-1.33 vs. MD<sub>SE</sub>: 1.62 × 10<sup>-3</sup> mm<sup>2</sup>/s) in STEAM compared to SE (p < 0.001, respectively). SNR was significantly higher for SE (72.3 ± 8.7) than for STEAM (p < 0.001). ICCs were excellent for FA in STEAM (≥0.911) and SE (0.960). For MD, ICCs were good for STEAM<sub>100ms-600ms</sub> (≥0.759) and SE (0.752). STEAM and SE exhibited excellent reliability for FA and good reliability for MD in the supraspinatus muscle. SNR was significantly higher in SE compared to STEAM.

NMR in BiomedicineVol. 38(1)
University of Zurich (CH), Universitätsklinik Balgrist (CH), Siemens Healthineers (Germany) (DE), Siemens (Switzerland) (CH)
Universität Zürich
Openalex Percentile: Top 25%
Advanced Neuroimaging Techniques and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.