Development and in situ application of actively heated fiber Bragg grating cable for soil water content measurement

The actively heated fiber-optic (AHFO) technology has emerged as a frontier and hotspot in soil water content measurement, offering advantages such as easy installation, large-scale distributed measurement capability, and resistance to electromagnetic interference. However, current AHFO water content sensors fail to simultaneously achieve high precision, applicability for deep soil, and automated real-time monitoring, thereby limiting their development and application. Therefore, this study introduces a novel actively heated fiber Bragg grating (AH-FBG) cable. Laboratory tests were conducted to assess the heating uniformity of the AH-FBG cable and to establish the temperature characteristic value ( T t ) – soil water content ( θ ) calibration formula for water content measurement. Subsequently, AH-FBG cables were deployed for in situ soil water content monitoring in a test pit on the Loess Plateau. Through two-year monitoring data verified the accuracy of the AH-FBG cable and elucidated the spatiotemporal distribution of in situ loess water content. Laboratory results demonstrated superior heating uniformity of AH-FBG cable, with a T t standard deviation of approximately 0.3 °C. In the field, the AH-FBG cable exhibited excellent performance in soil water content measurement, achieving a high accuracy of 0.023 cm 3 /cm 3 . Further analysis revealed that the θ fluctuation predominantly occurred within a 10 m depth from the soil surface, with an overall upward trend over the two-year monitoring period; the response of shallow θ to precipitation was significant but exhibited increasing hysteresis with depth; frequent precipitation significantly enhanced water infiltration depth. This study provides technical guidance for high-precision, quasi-distributed, automated and real-time water content measurement of deep soil. • A novel AH-FBG cable for soil water content measurement is developed. • The heating uniformity of the AH-FBG cable is tested through laboratory tests. • The feasibility and accuracy of the AH-FBG cable is verified through a field test. • The spatiotemporal distribution of in-situ loess water content is revealed.

Authors

Institutions

Publication Details

Journal
Journal of Rock Mechanics and Geotechnical Engineering
Published
2024-10-24
DOI
https://doi.org/10.1016/j.jrmge.2024.09.033
Citations
4
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and in situ application of actively heated fiber Bragg grating cable for soil water content measurement

Jie Liu, Xiaoyan Li, Bin Shi, Jun-Yi Guo et al.
4 citations
Journal of Rock Mechanics and Geotechnical Engineering
Advanced Fiber Optic Sensors
0.83
article

Development and in situ application of actively heated fiber Bragg grating cable for soil water content measurement

Jie Liu, Xiaoyan Li, Bin Shi, Jun-Yi Guo, Jin Liu, Yongping Tong, Xing Zheng, Yunqiang Wang, Mengya Sun
article en
4 citations

Abstract

The actively heated fiber-optic (AHFO) technology has emerged as a frontier and hotspot in soil water content measurement, offering advantages such as easy installation, large-scale distributed measurement capability, and resistance to electromagnetic interference. However, current AHFO water content sensors fail to simultaneously achieve high precision, applicability for deep soil, and automated real-time monitoring, thereby limiting their development and application. Therefore, this study introduces a novel actively heated fiber Bragg grating (AH-FBG) cable. Laboratory tests were conducted to assess the heating uniformity of the AH-FBG cable and to establish the temperature characteristic value ( T t ) – soil water content ( θ ) calibration formula for water content measurement. Subsequently, AH-FBG cables were deployed for in situ soil water content monitoring in a test pit on the Loess Plateau. Through two-year monitoring data verified the accuracy of the AH-FBG cable and elucidated the spatiotemporal distribution of in situ loess water content. Laboratory results demonstrated superior heating uniformity of AH-FBG cable, with a T t standard deviation of approximately 0.3 °C. In the field, the AH-FBG cable exhibited excellent performance in soil water content measurement, achieving a high accuracy of 0.023 cm 3 /cm 3 . Further analysis revealed that the θ fluctuation predominantly occurred within a 10 m depth from the soil surface, with an overall upward trend over the two-year monitoring period; the response of shallow θ to precipitation was significant but exhibited increasing hysteresis with depth; frequent precipitation significantly enhanced water infiltration depth. This study provides technical guidance for high-precision, quasi-distributed, automated and real-time water content measurement of deep soil. • A novel AH-FBG cable for soil water content measurement is developed. • The heating uniformity of the AH-FBG cable is tested through laboratory tests. • The feasibility and accuracy of the AH-FBG cable is verified through a field test. • The spatiotemporal distribution of in-situ loess water content is revealed.

Journal of Rock Mechanics and Geotechnical EngineeringVol. 17(7)
Chongqing University (CN), Hohai University (CN), Chinese Academy of Sciences (CN), Institute of Earth Environment (CN), Nanjing University (CN)
Openalex Percentile: Top 26%
Advanced Fiber Optic Sensors
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.