A novel technique for trehalose and sucrose determination in therapeutic monoclonal antibodies using a high-performance liquid chromatography–evaporative light scattering detector

Sucrose and trehalose are commonly used excipients in therapeutic monoclonal antibodies that play a pivotal role in ensuring the safety and stability of drugs. Though it is necessary to control the concentrations of these substances during the quality control of their release, there is currently no comprehensive method for simultaneously determining sucrose and trehalose concentrations. Herein, we established a high-performance liquid chromatography-evaporative light scattering detector (HPLC-ELSD) method and validated it in accordance with the International Council for Harmonization Q2 guidelines. This method utilized the Poroshell 120 HILIC-Z chromatographic column and effectively separated sucrose and trehalose with a detection limit of 0.001 mg/mL. The accuracy recovery rate was within a range of 90%-110 %, and the precision relative standard deviations were all less than 5.0 % (n = 6). The method thus demonstrated good repeatability and linearity, making it suitable for determining the sucrose and trehalose concentrations in therapeutic monoclonal antibodies.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-10-24
DOI
https://doi.org/10.1016/j.heliyon.2024.e39809
Citations
1
Primary Topic
Protein purification and stability
Type
article
Field-Weighted Citation Impact
0.23

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel technique for trehalose and sucrose determination in therapeutic monoclonal antibodies using a high-performance liquid chromatography–evaporative light scattering detector

Xiaojuan Yu, Z. Xing, Chuanfei Yu, Lan Wang
1 citations
Heliyon
Protein purification and stability
0.23
article

A novel technique for trehalose and sucrose determination in therapeutic monoclonal antibodies using a high-performance liquid chromatography–evaporative light scattering detector

Xiaojuan Yu, Z. Xing, Chuanfei Yu, Lan Wang
article en
1 citations

Abstract

Sucrose and trehalose are commonly used excipients in therapeutic monoclonal antibodies that play a pivotal role in ensuring the safety and stability of drugs. Though it is necessary to control the concentrations of these substances during the quality control of their release, there is currently no comprehensive method for simultaneously determining sucrose and trehalose concentrations. Herein, we established a high-performance liquid chromatography-evaporative light scattering detector (HPLC-ELSD) method and validated it in accordance with the International Council for Harmonization Q2 guidelines. This method utilized the Poroshell 120 HILIC-Z chromatographic column and effectively separated sucrose and trehalose with a detection limit of 0.001 mg/mL. The accuracy recovery rate was within a range of 90%-110 %, and the precision relative standard deviations were all less than 5.0 % (n = 6). The method thus demonstrated good repeatability and linearity, making it suitable for determining the sucrose and trehalose concentrations in therapeutic monoclonal antibodies.

HeliyonVol. 10(21)
National Institutes for Food and Drug Control (CN)
National Natural Science Foundation of China, Key Technologies Research and Development Program, National Key Research and Development Program of China
Openalex Percentile: Top 42%
Protein purification and stability
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A novel technique for trehalose and sucrose determination in therapeutic monoclonal antibodies using a high-performance liquid chromatography–evaporative light scattering detector — Xiaojuan Yu, Z. Xing, et al. · Heliyon (2024) | TGRS Research Map | TGRS