International Anesthesia Research Society 2024 Annual Meeting

Introduction: Exertional dehydration correlates with decreased athletic performance and can lead to systemic collapse and death. Therefore, appropriate hydration monitoring is important, but unfortunately, it is under-investigated (1). While various «hydration» monitoring technologies are available on the market, few have been critically examined, with measurement of body weight the only viable practice for monitoring hydration and exertional dehydration (2). Non-invasive Venous Waveform Analysis (NIVA) has recently been described in adults as a non-invasive method for monitoring volume status, both in congested states and during acute blood loss (3,4). This study investigated how NIVA monitors hydration in relation to the established practice of total body water monitoring in track athletes at Miami University, Oxford, Ohio. Methods: Fifteen athletes performed routine cardiovascular aerobic exercises varying in duration from 45 minutes to 120 minutes, resulting in a total of 43 pre- and post-exercise assessments. NIVA measurements were obtained by applying a device containing a piezoelectric sensor to the volar aspect of the wrist 10 minutes prior to the start of exercise, and after a 15-minute rest period following exercise. All athletes were allowed to hydrate as desired/needed, and intake volumes were recorded. Venous waveform signals were analyzed to provide a quantitative value [Volume Index Analysis (VIA)] Score. Body weights and percent body water were concurrently measured using a TANITA in-body scale (Tanita Corporation of America, Inc., Arlington Heights, IL, USA). Results: The change ( ) in VIA Score from pre-exercise to post-exercise demonstrated a significant linear correlation with the change in total body water percentage ( total body water %; r=0.32, p< 0.05, n=41). Conclusions: NIVA represents a non-invasive, individualized approach to hydration monitoring and management in athletes. The VIA Score demonstrated a significant correlation with the total body water percentage. Further studies are needed to assess the use of the NIVA device in monitoring and modulating dehydration in performance athletes and to evaluate the impact of using the VIA Score on athlete performance and health.

Publication Details

Journal
Anesthesia & Analgesia
Published
2024-10-24
DOI
https://doi.org/10.1213/01.ane.0001083496.23266.e9
Primary Topic
Cardiac, Anesthesia and Surgical Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

International Anesthesia Research Society 2024 Annual Meeting

Anesthesia & Analgesia
Cardiac, Anesthesia and Surgical Outcomes
article

International Anesthesia Research Society 2024 Annual Meeting

article en

Abstract

Introduction: Exertional dehydration correlates with decreased athletic performance and can lead to systemic collapse and death. Therefore, appropriate hydration monitoring is important, but unfortunately, it is under-investigated (1). While various «hydration» monitoring technologies are available on the market, few have been critically examined, with measurement of body weight the only viable practice for monitoring hydration and exertional dehydration (2). Non-invasive Venous Waveform Analysis (NIVA) has recently been described in adults as a non-invasive method for monitoring volume status, both in congested states and during acute blood loss (3,4). This study investigated how NIVA monitors hydration in relation to the established practice of total body water monitoring in track athletes at Miami University, Oxford, Ohio. Methods: Fifteen athletes performed routine cardiovascular aerobic exercises varying in duration from 45 minutes to 120 minutes, resulting in a total of 43 pre- and post-exercise assessments. NIVA measurements were obtained by applying a device containing a piezoelectric sensor to the volar aspect of the wrist 10 minutes prior to the start of exercise, and after a 15-minute rest period following exercise. All athletes were allowed to hydrate as desired/needed, and intake volumes were recorded. Venous waveform signals were analyzed to provide a quantitative value [Volume Index Analysis (VIA)] Score. Body weights and percent body water were concurrently measured using a TANITA in-body scale (Tanita Corporation of America, Inc., Arlington Heights, IL, USA). Results: The change ( ) in VIA Score from pre-exercise to post-exercise demonstrated a significant linear correlation with the change in total body water percentage ( total body water %; r=0.32, p< 0.05, n=41). Conclusions: NIVA represents a non-invasive, individualized approach to hydration monitoring and management in athletes. The VIA Score demonstrated a significant correlation with the total body water percentage. Further studies are needed to assess the use of the NIVA device in monitoring and modulating dehydration in performance athletes and to evaluate the impact of using the VIA Score on athlete performance and health.

Anesthesia & AnalgesiaVol. 139(5S)
Openalex Percentile: Top 67%
Cardiac, Anesthesia and Surgical Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

International Anesthesia Research Society 2024 Annual Meeting · Anesthesia & Analgesia (2024) | TGRS Research Map | TGRS