One-Second Touchscreen Disinfection with Internal UVC-LEDs

The transmission of pathogens via touchscreens is a concern both in medical environments regarding nosocomial infections and in public spaces. This study presents the development of a self-disinfecting touchscreen system and its implementation into an existing medical device. The disinfection was achieved by irradiating UVC light laterally into the quartz front glass of the touchscreen. The system also included a two-stage safety shutdown feature to protect users from UVC exposure. To detect the presence of the user’s hand, a proximity sensor behind the front glass of the touch screen was installed in combination with touch input registration. A rapid disinfection of staphylococci was achieved without compromising usability and user safety. The prototype demonstrated a bacterial reduction of 99.96% or 3.4 (±0.36) log levels in less than 1 s. The results suggest that the technology has the potential to make a significant contribution to reducing the transmission of infections in healthcare settings and beyond.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2024-10-24
DOI
https://doi.org/10.3390/photonics11111001
Citations
1
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

One-Second Touchscreen Disinfection with Internal UVC-LEDs

Martin Heßling, Klaus Noller, Ben Sicks
1 citations
Photonics
Biosensors and Analytical Detection
0.18
article

One-Second Touchscreen Disinfection with Internal UVC-LEDs

Martin Heßling, Klaus Noller, Ben Sicks
article en
1 citations

Abstract

The transmission of pathogens via touchscreens is a concern both in medical environments regarding nosocomial infections and in public spaces. This study presents the development of a self-disinfecting touchscreen system and its implementation into an existing medical device. The disinfection was achieved by irradiating UVC light laterally into the quartz front glass of the touchscreen. The system also included a two-stage safety shutdown feature to protect users from UVC exposure. To detect the presence of the user’s hand, a proximity sensor behind the front glass of the touch screen was installed in combination with touch input registration. A rapid disinfection of staphylococci was achieved without compromising usability and user safety. The prototype demonstrated a bacterial reduction of 99.96% or 3.4 (±0.36) log levels in less than 1 s. The results suggest that the technology has the potential to make a significant contribution to reducing the transmission of infections in healthcare settings and beyond.

PhotonicsVol. 11(11)
Technische Hochschule Ulm (DE)
Openalex Percentile: Top 51%
Biosensors and Analytical Detection
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

One-Second Touchscreen Disinfection with Internal UVC-LEDs — Martin Heßling, Klaus Noller, et al. · Photonics (2024) | TGRS Research Map | TGRS