Coefficients of variation analyses of internal quality control status for blood lead in China from 2015 to 2023

BackgroundBlood lead test is widely conducted in Chinese laboratories, while the imprecision of blood lead measurement based on internal quality control (IQC) across China has not been comprehensively evaluated nowadays.MethodsUsing the IQC data of blood lead collected through a web-based external quality assessment (EQA) reporting system, we analysed current coefficients of variation (CVs) of blood lead from 2015 to 2023 among Chinese laboratories. Two allowable total error (TEa) imprecision levels from EQA were applied to calculate the pass rates, namely percentages of laboratories meeting precision quality specifications. Besides, CV values and pass rates by different subgroups were further performed to assess potential differences.ResultsGenerally, median CV values significantly declined year by year from 6.8% in February 2015 to 5.9% in March 2023. The pass rates based on 1/3 TEa showed upward trends increasing from 15.3% in February 2015 to 20.0% in March 2023, but these percentages were non-ideal with less than 25%. No significant differences in CVs were found between tertiary hospitals and non-tertiary hospitals and between accredited and non-accredited laboratories. Significant time trends were observed in tertiary hospitals and non-accredited laboratories. As for manufacturers, Bohui and self-made QC sample were most widely used with obvious interannual declining trends of CVs.ConclusionsThe CVs of blood lead demonstrated continuous overall improvements in the past twenty years. However, relatively lower pass rates indicated the non-ideal imprecision performance, and more proper performance specifications are warranted. Thus, imprecision improvement and ongoing investigation for blood lead IQC are still needed.

Authors

Institutions

Publication Details

Journal
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Published
2024-10-23
DOI
https://doi.org/10.1177/00045632241297885
Primary Topic
Advanced Statistical Process Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coefficients of variation analyses of internal quality control status for blood lead in China from 2015 to 2023

Chuanbao Zhang, Shuai Yuan, Jie Zeng, Han Ma et al.
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Advanced Statistical Process Monitoring
article

Coefficients of variation analyses of internal quality control status for blood lead in China from 2015 to 2023

Chuanbao Zhang, Shuai Yuan, Jie Zeng, Han Ma, Jiali Liu, Zhiguo Wang, Chao Zhang, Ying Yan, Wei Wang, Na Dong
article en

Abstract

BackgroundBlood lead test is widely conducted in Chinese laboratories, while the imprecision of blood lead measurement based on internal quality control (IQC) across China has not been comprehensively evaluated nowadays.MethodsUsing the IQC data of blood lead collected through a web-based external quality assessment (EQA) reporting system, we analysed current coefficients of variation (CVs) of blood lead from 2015 to 2023 among Chinese laboratories. Two allowable total error (TEa) imprecision levels from EQA were applied to calculate the pass rates, namely percentages of laboratories meeting precision quality specifications. Besides, CV values and pass rates by different subgroups were further performed to assess potential differences.ResultsGenerally, median CV values significantly declined year by year from 6.8% in February 2015 to 5.9% in March 2023. The pass rates based on 1/3 TEa showed upward trends increasing from 15.3% in February 2015 to 20.0% in March 2023, but these percentages were non-ideal with less than 25%. No significant differences in CVs were found between tertiary hospitals and non-tertiary hospitals and between accredited and non-accredited laboratories. Significant time trends were observed in tertiary hospitals and non-accredited laboratories. As for manufacturers, Bohui and self-made QC sample were most widely used with obvious interannual declining trends of CVs.ConclusionsThe CVs of blood lead demonstrated continuous overall improvements in the past twenty years. However, relatively lower pass rates indicated the non-ideal imprecision performance, and more proper performance specifications are warranted. Thus, imprecision improvement and ongoing investigation for blood lead IQC are still needed.

Annals of Clinical Biochemistry International Journal of Laboratory MedicineVol. 62(3)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Beijing Hospital (CN), National Center for Clinical Laboratories (CN)
Openalex Percentile: Top 81%
Advanced Statistical Process Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.