Low-temperature Deposited Highly Sensitive Integrated All-Solid Electrodes for Electrochemical pH Detection

This article describes the process of fabricating an integrated all-solid electrode (IASE) by integrating thin films of titanium dioxide (TiO<i>2</i>) and silver/silver chloride (Ag/AgCl) onto an indium tin oxide (ITO) substrate. The fabrication of a pH sensing electrode (SE) involved utilizing a spin-coated thin film composed of TiO<i>2</i>. Thermally produced thin films of Ag/AgCl were used to develop solid reference electrodes (RE). The present work examined the impact of the drying process on the pH sensitivity and linearity of the low-temperature deposited IASE. The drying procedure was carried out within a temperature range from room temperature to 100°C. The investigation involved the examination of crystallinity, surface morphology, and thin film composition through the utilization of field effect scanning electron microscopy (FESEM), X-ray diffraction (XRD), and energy-dispersive X-ray (EDX) methods. In addition, a comparison was made between the pH sensing performance of the IASE and a commercially available Ag/AgCl RE. The findings of this research demonstrate that the IASE sample, which underwent a drying process at a temperature of 100°C, exhibited remarkable sensitivity and linearity values of 66.7 mV/pH and 0.9827, separately, when compared to the commercially available RE.

Authors

Publication Details

Journal
Pertanika journal of science & technology
Published
2024-10-23
DOI
https://doi.org/10.47836/pjst.32.6.08
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-temperature Deposited Highly Sensitive Integrated All-Solid Electrodes for Electrochemical pH Detection

Norhidayatul Hikmee Mahzan, Sukreen Hana Herman, Zuhani Ismail Khan, Rosalena Irma Alip et al.
Pertanika journal of science & technology
Analytical Chemistry and Sensors
article

Low-temperature Deposited Highly Sensitive Integrated All-Solid Electrodes for Electrochemical pH Detection

Norhidayatul Hikmee Mahzan, Sukreen Hana Herman, Zuhani Ismail Khan, Rosalena Irma Alip, Shaiful Bakhtiar Hashim
article en

Abstract

This article describes the process of fabricating an integrated all-solid electrode (IASE) by integrating thin films of titanium dioxide (TiO<i>2</i>) and silver/silver chloride (Ag/AgCl) onto an indium tin oxide (ITO) substrate. The fabrication of a pH sensing electrode (SE) involved utilizing a spin-coated thin film composed of TiO<i>2</i>. Thermally produced thin films of Ag/AgCl were used to develop solid reference electrodes (RE). The present work examined the impact of the drying process on the pH sensitivity and linearity of the low-temperature deposited IASE. The drying procedure was carried out within a temperature range from room temperature to 100°C. The investigation involved the examination of crystallinity, surface morphology, and thin film composition through the utilization of field effect scanning electron microscopy (FESEM), X-ray diffraction (XRD), and energy-dispersive X-ray (EDX) methods. In addition, a comparison was made between the pH sensing performance of the IASE and a commercially available Ag/AgCl RE. The findings of this research demonstrate that the IASE sample, which underwent a drying process at a temperature of 100°C, exhibited remarkable sensitivity and linearity values of 66.7 mV/pH and 0.9827, separately, when compared to the commercially available RE.

Pertanika journal of science & technologyVol. 32(6)
Openalex Percentile: Top 81%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Low-temperature Deposited Highly Sensitive Integrated All-Solid Electrodes for Electrochemical pH Detection — Norhidayatul Hikmee Mahzan, Sukreen Hana Herman, et al. · Pertanika journal of science & technology (2024) | TGRS Research Map | TGRS