Rapid Liquid Chromatography–Tandem Mass Spectrometry Method for Determination of Total and Free Testosterone in Human Serum and Its Application to Monitoring Biomarker Response of Elite Athletes

Total testosterone (TT) and free testosterone (FT) are important biochemical markers for anabolism of the human body, and can also serve as early screening indicators for overtraining syndrome (OTS). Presently, there is no fast and reliable serum TT and FT determination method in the field of sport science that can meet the requirements of sports research. Thus, a rapid and accurate determination method for serum TT and FT to fill the gap is needed urgently in sports training. Herein, a simple and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of TT and FT in serum was developed and fully validated, followed by the application of professional athletes in training monitoring. Efficient pretreatments based on only one-step liquid-liquid extraction (LLE) for TT and one-step LLE after a 20 min ultrafiltration for FT were adopted in this study, and the isotope internal standard of testosterone-13C3 was used to ensure the reliability of the whole procedure. A linear range of four orders of magnitude with 0.02-100 ng/mL can meet the concentration range requirement between a higher limit for male TT and a lower limit for female FT. The accuracy, precision, stability, and matrix effect were all within the limits of the guidelines. The serum TT and FT levels of 200 professional athletes (98 male athletes and 102 female athletes) were investigated by this method. Serum TT, FT, and FT/TT levels of professional athletes were significantly higher than the general population, and serum TT levels were significantly higher by LC-MS/MS than by a chemiluminescence immunoassay. In conclusion, the LC-MS/MS method for TT and FT measurement developed in this study is time-saving and easy to operate, which can be used as a reliable method for the determination of serum TT and FT in sports training, offering valuable information for monitoring anabolism of athletes and screening OTS in the early stage.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2024-10-23
DOI
https://doi.org/10.3390/molecules29215007
Citations
2
Primary Topic
Hormonal and reproductive studies
Type
article
Field-Weighted Citation Impact
0.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid Liquid Chromatography–Tandem Mass Spectrometry Method for Determination of Total and Free Testosterone in Human Serum and Its Application to Monitoring Biomarker Response of Elite Athletes

Xingya Yang, Hang Yu, Jianli Zhang, Yan Wang et al.
2 citations
Molecules
Hormonal and reproductive studies
0.72
article

Rapid Liquid Chromatography–Tandem Mass Spectrometry Method for Determination of Total and Free Testosterone in Human Serum and Its Application to Monitoring Biomarker Response of Elite Athletes

Xingya Yang, Hang Yu, Jianli Zhang, Yan Wang, Yu-Lin Shen
article en
2 citations

Abstract

Total testosterone (TT) and free testosterone (FT) are important biochemical markers for anabolism of the human body, and can also serve as early screening indicators for overtraining syndrome (OTS). Presently, there is no fast and reliable serum TT and FT determination method in the field of sport science that can meet the requirements of sports research. Thus, a rapid and accurate determination method for serum TT and FT to fill the gap is needed urgently in sports training. Herein, a simple and reliable liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of TT and FT in serum was developed and fully validated, followed by the application of professional athletes in training monitoring. Efficient pretreatments based on only one-step liquid-liquid extraction (LLE) for TT and one-step LLE after a 20 min ultrafiltration for FT were adopted in this study, and the isotope internal standard of testosterone-13C3 was used to ensure the reliability of the whole procedure. A linear range of four orders of magnitude with 0.02-100 ng/mL can meet the concentration range requirement between a higher limit for male TT and a lower limit for female FT. The accuracy, precision, stability, and matrix effect were all within the limits of the guidelines. The serum TT and FT levels of 200 professional athletes (98 male athletes and 102 female athletes) were investigated by this method. Serum TT, FT, and FT/TT levels of professional athletes were significantly higher than the general population, and serum TT levels were significantly higher by LC-MS/MS than by a chemiluminescence immunoassay. In conclusion, the LC-MS/MS method for TT and FT measurement developed in this study is time-saving and easy to operate, which can be used as a reliable method for the determination of serum TT and FT in sports training, offering valuable information for monitoring anabolism of athletes and screening OTS in the early stage.

MoleculesVol. 29(21)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), General Administration of Sport of China (CN), China Institute of Sport Science (CN)
Openalex Percentile: Top 25%
Hormonal and reproductive studies
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.