In Vitro Testing of Protective Eye Wear in Blocking Blue Light from Dental Light Curing Unit

Aim: To evaluate the ef?cacy of wearing protective eyewear in preventing harmful Dental light-curing units (LCUs). Background: Dental light-curing units generate blue light, capable of inducing soft-tissue burns and ocular harm like retinal damage. The intensity of blue light emitted by dental Light Curing Units is substantially higher, thereby potentially constituting a significant "blue light hazard." Material and Methods: To study the effect of protective glasses, reverse methodology was followed as the effect of blue light on the eye is difficult to measure; Circular composite disc samples were grouped into two, one of which was polymerized directly while the other had protective glass in between, Fourier transform infrared spectroscopy (FTIR) analysis was done and the degree of conversion was calculated. Results: Data obtained were analysed using One Way ANOVA. The mean values for "Degree of Conversion" in Group I (Without Protective Glass) is 1.334 +512 and for Group II (with protective glass) is -2.623 + 1.544 .One Way ANOVA revealed statistically significant difference between Group I and Group II (p=0.000) Conclusion: Within the limitations of this in vitro study, it can be concluded that the protective glasses are successful in filtering the harmful blue light emitted by LCU and should be used in day-to-day practice to improve the amount of light they deliver to the restoration from the LCU and prevent any harm to the ocular tissues. Clinical implications: Blue light filtering glasses in a dental operatory provide optimum protection, and the operator can safely watch and improve the amount of light delivered to the restoration from the LCU.

Authors

Institutions

Publication Details

Journal
JOURNAL OF CLINICAL PROSTHODONTICS AND IMPLANTOLOGY
Published
2024-10-18
DOI
https://doi.org/10.55995/j-cpi.2024014
Primary Topic
Ocular and Laser Science Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In Vitro Testing of Protective Eye Wear in Blocking Blue Light from Dental Light Curing Unit

Vidyashree Nandini, Shiney Boruah, Meghna Das
JOURNAL OF CLINICAL PROSTHODONTICS AND IMPLANTOLOGY
Ocular and Laser Science Research
article

In Vitro Testing of Protective Eye Wear in Blocking Blue Light from Dental Light Curing Unit

Vidyashree Nandini, Shiney Boruah, Meghna Das
article en

Abstract

Aim: To evaluate the ef?cacy of wearing protective eyewear in preventing harmful Dental light-curing units (LCUs). Background: Dental light-curing units generate blue light, capable of inducing soft-tissue burns and ocular harm like retinal damage. The intensity of blue light emitted by dental Light Curing Units is substantially higher, thereby potentially constituting a significant "blue light hazard." Material and Methods: To study the effect of protective glasses, reverse methodology was followed as the effect of blue light on the eye is difficult to measure; Circular composite disc samples were grouped into two, one of which was polymerized directly while the other had protective glass in between, Fourier transform infrared spectroscopy (FTIR) analysis was done and the degree of conversion was calculated. Results: Data obtained were analysed using One Way ANOVA. The mean values for "Degree of Conversion" in Group I (Without Protective Glass) is 1.334 +512 and for Group II (with protective glass) is -2.623 + 1.544 .One Way ANOVA revealed statistically significant difference between Group I and Group II (p=0.000) Conclusion: Within the limitations of this in vitro study, it can be concluded that the protective glasses are successful in filtering the harmful blue light emitted by LCU and should be used in day-to-day practice to improve the amount of light they deliver to the restoration from the LCU and prevent any harm to the ocular tissues. Clinical implications: Blue light filtering glasses in a dental operatory provide optimum protection, and the operator can safely watch and improve the amount of light delivered to the restoration from the LCU.

JOURNAL OF CLINICAL PROSTHODONTICS AND IMPLANTOLOGYVol. 6(2)
SRM Institute of Science and Technology (IN), SRM Dental College (IN)
Openalex Percentile: Top 69%
Ocular and Laser Science Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.