Automated deep learning-based bone mineral density assessment for opportunistic osteoporosis screening using various CT protocols with multi-vendor scanners
This retrospective study examined the diagnostic efficacy of automated deep learning-based bone mineral density (DL-BMD) measurements for osteoporosis screening using 422 CT datasets from four vendors in two medical centers, encompassing 159 chest, 156 abdominal, and 107 lumbar spine datasets. DL-BMD values on L1 and L2 vertebral bodies were compared with manual BMD (m-BMD) measurements using Pearson's correlation and intraclass correlation coefficients. Strong agreement was found between m-BMD and DL-BMD in total CT scans (r = 0.953, p < 0.001). The diagnostic performance of DL-BMD was assessed using receiver operating characteristic analysis for osteoporosis and low BMD by dual-energy x-ray absorptiometry (DXA) and m-BMD. Compared to DXA, DL-BMD demonstrated an AUC of 0.790 (95% CI 0.733-0.839) for low BMD and 0.769 (95% CI 0.710-0.820) for osteoporosis, with sensitivity, specificity, and accuracy of 80.8% (95% CI 74.2-86.3%), 56.3% (95% CI 43.4-68.6%), and 74.3% (95% CI 68.3-79.7%) for low BMD and 65.4% (95% CI 50.9-78.0%), 70.9% (95% CI 63.8-77.3%), and 69.7% (95% CI 63.5-75.4%) for osteoporosis, respectively. Compared to m-BMD, DL-BMD showed an AUC of 0.983 (95% CI 0.973-0.993) for low BMD and 0.972 (95% CI 0.958-0.987) for osteoporosis, with sensitivity, specificity, and accuracy of 97.3% (95% CI 94.5-98.9%), 85.2% (95% CI 78.8-90.3%), and 92.7% (95% CI 89.7-95.0%) for low BMD and 94.4% (95% CI 88.3-97.9%), 89.5% (95% CI 85.6-92.7%), and 90.8% (95% CI 87.6-93.4%) for osteoporosis, respectively. The DL-based method can provide accurate and reliable BMD assessments across diverse CT protocols and scanners.
Authors
- Heejun Park (ORCID: https://orcid.org/0000-0001-8250-1690)
- Jemyoung Lee (ORCID: https://orcid.org/0000-0001-7248-3652)
- Ok Hee Woo (ORCID: https://orcid.org/0000-0003-3953-933X)
- Sangseok Oh
- Zepa Yang
- Woo Young Kang (ORCID: https://orcid.org/0000-0003-3888-8490)
Institutions
- Seoul National University (KR)
- Korea University Medical Center (KR)
Publication Details
- Journal
- Scientific Reports
- Published
- 2024-10-23
- DOI
- https://doi.org/10.1038/s41598-024-73709-w
- Citations
- 20
- Primary Topic
- Radiomics and Machine Learning in Medical Imaging
- Type
- article
- Field-Weighted Citation Impact
- 8.09
Funders
- Ministry of Trade, Industry and Energy
- Ministry of Food and Drug Safety