U-Net and Its Variants Based Automatic Tracking of Radial Artery in Ultrasonic Short-Axis Views: A Pilot Study

<b>Background/Objectives:</b> Radial artery tracking (RAT) in the short-axis view is a pivotal step for ultrasound-guided radial artery catheterization (RAC), which is widely employed in various clinical settings. To eliminate disparities and lay the foundations for automated procedures, a pilot study was conducted to explore the feasibility of U-Net and its variants in automatic RAT. <b>Methods:</b> Approved by the institutional ethics committee, patients as potential RAC candidates were enrolled, and the radial arteries were continuously scanned by B-mode ultrasonography. All acquired videos were processed into standardized images, and randomly divided into training, validation, and test sets in an 8:1:1 ratio. Deep learning models, including U-Net and its variants, such as Attention U-Net, UNet++, Res-UNet, TransUNet, and UNeXt, were utilized for automatic RAT. The performance of the deep learning architectures was assessed using loss functions, dice similarity coefficient (DSC), and Jaccard similarity coefficient (JSC). Performance differences were analyzed using the Kruskal-Wallis test. <b>Results:</b> The independent datasets comprised 7233 images extracted from 178 videos of 135 patients (53.3% women; mean age: 41.6 years). Consistent convergence of loss functions between the training and validation sets was achieved for all models except Attention U-Net. Res-UNet emerged as the optimal architecture in terms of DSC and JSC (93.14% and 87.93%), indicating a significant improvement compared to U-Net (91.79% vs. 86.19%, <i>p</i> < 0.05) and Attention U-Net (91.20% vs. 85.02%, <i>p</i> < 0.05). <b>Conclusions:</b> This pilot study validates the feasibility of U-Net and its variants in automatic RAT, highlighting the predominant performance of Res-UNet among the evaluated architectures.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2024-10-23
DOI
https://doi.org/10.3390/diagnostics14212358
Citations
1
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

U-Net and Its Variants Based Automatic Tracking of Radial Artery in Ultrasonic Short-Axis Views: A Pilot Study

Chunrong Wang, Yuelun Zhang, Xinran Shi, Ruiyang Gao et al.
1 citations
Diagnostics
Surgical Simulation and Training
0.57
article

U-Net and Its Variants Based Automatic Tracking of Radial Artery in Ultrasonic Short-Axis Views: A Pilot Study

Chunrong Wang, Yuelun Zhang, Xinran Shi, Ruiyang Gao, Le Shen, Xue Yang, Chunhua Yu, Zhuhuang Zhou, Yuan Tian, Jiaxin Lang
article en
1 citations

Abstract

<b>Background/Objectives:</b> Radial artery tracking (RAT) in the short-axis view is a pivotal step for ultrasound-guided radial artery catheterization (RAC), which is widely employed in various clinical settings. To eliminate disparities and lay the foundations for automated procedures, a pilot study was conducted to explore the feasibility of U-Net and its variants in automatic RAT. <b>Methods:</b> Approved by the institutional ethics committee, patients as potential RAC candidates were enrolled, and the radial arteries were continuously scanned by B-mode ultrasonography. All acquired videos were processed into standardized images, and randomly divided into training, validation, and test sets in an 8:1:1 ratio. Deep learning models, including U-Net and its variants, such as Attention U-Net, UNet++, Res-UNet, TransUNet, and UNeXt, were utilized for automatic RAT. The performance of the deep learning architectures was assessed using loss functions, dice similarity coefficient (DSC), and Jaccard similarity coefficient (JSC). Performance differences were analyzed using the Kruskal-Wallis test. <b>Results:</b> The independent datasets comprised 7233 images extracted from 178 videos of 135 patients (53.3% women; mean age: 41.6 years). Consistent convergence of loss functions between the training and validation sets was achieved for all models except Attention U-Net. Res-UNet emerged as the optimal architecture in terms of DSC and JSC (93.14% and 87.93%), indicating a significant improvement compared to U-Net (91.79% vs. 86.19%, <i>p</i> < 0.05) and Attention U-Net (91.20% vs. 85.02%, <i>p</i> < 0.05). <b>Conclusions:</b> This pilot study validates the feasibility of U-Net and its variants in automatic RAT, highlighting the predominant performance of Res-UNet among the evaluated architectures.

DiagnosticsVol. 14(21)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN), Beijing University of Technology (CN)
Openalex Percentile: Top 28%
Surgical Simulation and Training
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.