Thin Delivery Stents Can Obviate the Need for Additional Fistula Dilatation of Large Diameter in Endoscopic Ultrasound-Guided Hepaticogastrostomy

<b>Background/Objectives:</b> Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) often requires fistula dilation owing to the placement of a large diameter of the delivery stent. The recently developed delivery devices, which are as thin as 5.9/6.0 Fr, may save the need for fistula dilation. Therefore, we investigated whether large fistula dilation would be required or not in the case of this newly developed thin-diameter delivery stents. <b>Methods:</b> We conducted a retrospective study involving 33 patients implemented with a self-expandable metal stent (SEMS) during EUS-HGS. The patients were categorized based on the delivery device diameter into thin (n = 13; delivery device diameter: 5.9/6.0 Fr) and thick (n = 20; delivery device diameter: 8.5 Fr) groups. We compared the initial rate of success, technical success, and clinical success between the thin and thick groups. The initial rate of success was defined as successful stent placement without a balloon or large diameter mechanical dilation. <b>Results:</b> The rate of the initial stenting success was significantly higher in the thin group (100% [13/13]) compared with that in the thick group (65.0% [13/20]) (<i>p</i> = 0.027). In the thick group, seven cases with technical difficulty in terms of stent placement could be successfully completed with additional fistula dilation with a 9 Fr bougie dilator or 4 mm balloon dilator; this resulted in a technical success of 100% in both groups ultimately. The rate of clinical success was 100% and 95.0% in the thin and thick groups, respectively (<i>p</i> = 1.00). <b>Conclusions:</b> Thin delivery stents may facilitate stent placement without the need for a balloon fistula or large-diameter mechanical dilation.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2024-10-23
DOI
https://doi.org/10.3390/jcm13216328
Primary Topic
Gallbladder and Bile Duct Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thin Delivery Stents Can Obviate the Need for Additional Fistula Dilatation of Large Diameter in Endoscopic Ultrasound-Guided Hepaticogastrostomy

Atsushi Nakajima, Shin Yagi, Sho Hasegawa, Kensuke Kubota et al.
Journal of Clinical Medicine
Gallbladder and Bile Duct Disorders
article

Thin Delivery Stents Can Obviate the Need for Additional Fistula Dilatation of Large Diameter in Endoscopic Ultrasound-Guided Hepaticogastrostomy

Atsushi Nakajima, Shin Yagi, Sho Hasegawa, Kensuke Kubota, Itaru Endo, Tomoki Ogata, Yusuke Kurita, Noritoshi Kobayashi, Kunihiro Hosono, Takamitsu Sato
article en

Abstract

<b>Background/Objectives:</b> Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) often requires fistula dilation owing to the placement of a large diameter of the delivery stent. The recently developed delivery devices, which are as thin as 5.9/6.0 Fr, may save the need for fistula dilation. Therefore, we investigated whether large fistula dilation would be required or not in the case of this newly developed thin-diameter delivery stents. <b>Methods:</b> We conducted a retrospective study involving 33 patients implemented with a self-expandable metal stent (SEMS) during EUS-HGS. The patients were categorized based on the delivery device diameter into thin (n = 13; delivery device diameter: 5.9/6.0 Fr) and thick (n = 20; delivery device diameter: 8.5 Fr) groups. We compared the initial rate of success, technical success, and clinical success between the thin and thick groups. The initial rate of success was defined as successful stent placement without a balloon or large diameter mechanical dilation. <b>Results:</b> The rate of the initial stenting success was significantly higher in the thin group (100% [13/13]) compared with that in the thick group (65.0% [13/20]) (<i>p</i> = 0.027). In the thick group, seven cases with technical difficulty in terms of stent placement could be successfully completed with additional fistula dilation with a 9 Fr bougie dilator or 4 mm balloon dilator; this resulted in a technical success of 100% in both groups ultimately. The rate of clinical success was 100% and 95.0% in the thin and thick groups, respectively (<i>p</i> = 1.00). <b>Conclusions:</b> Thin delivery stents may facilitate stent placement without the need for a balloon fistula or large-diameter mechanical dilation.

Journal of Clinical MedicineVol. 13(21)
Yokohama City University Hospital (JP), Yokohama City University (JP)
Openalex Percentile: Top 66%
Gallbladder and Bile Duct Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.