Effects of Pressure, Surfactant Concentration, and Heat Flux on Pool Boiling Using Expanding Microchanneled Surface for Two-Phase Immersion Cooling

Deionized water is replacing fluorinated liquids as the preferred choice for two-phase immersion cooling in data centers. Yet, insufficient bubble removal capability at low saturated pressure is a key challenge hindering the widespread application. To solve this issue, this study employs non-ionic surfactant (Tween 20) and asymmetric structures (expanding microchannel) to enhance the boiling performances of deionized water under sub-atmospheric pressure. The research examines the effects of pressure (8.8~38.5 kPa), surfactant concentration (0.1~0.5 mL/L), and heat flux density (10~180 W/cm<sup>2</sup>) on the boiling heat transfer characteristics and analyzes the mechanism of unusual temperature oscillations induced by surfactants. It was found that the trade-off between the sub-atmospheric pressure, surface tension coefficient, and reduced static contact angle results in pronounced intermittent boiling on the heated surface. Even with the addition of surfactants, the improvement in heat transfer requires demanding conditions. Boiling enhancement throughout all heat flux conditions was achieved when the surfactant concentration was higher than 0.2 mL/L for the expanding microchanneled surface. The heat transfer coefficient reached 6.89 W·cm<sup>-2</sup>·K<sup>-1</sup> under 8.8 kPa, which was 45% higher than without the surfactant. Under the same heat flux and sub-atmospheric pressure, as the concentration increased from 0.1 to 0.5 mL/L, the amplitudes of temperature fluctuation of the plane surface and expanding microchanneled surface decreased from 10 K to 2 K and 18 K to 1 K, respectively. The onset of nucleate boiling and wall superheat of the expanding microchanneled surface gradually decreased with the increase in surfactant concentration, where the onset of nucleate boiling decreased by 10.54 K. When the heat flux is 160 W/cm<sup>2</sup>, the wall superheat is reduced by 12.8 K.

Authors

Institutions

Publication Details

Journal
Materials
Published
2024-10-23
DOI
https://doi.org/10.3390/ma17215155
Citations
4
Primary Topic
Heat Transfer and Boiling Studies
Type
article
Field-Weighted Citation Impact
0.85

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Pressure, Surfactant Concentration, and Heat Flux on Pool Boiling Using Expanding Microchanneled Surface for Two-Phase Immersion Cooling

Dengwei Fu, Chaobin Dang, Yifei Hu, Sihui Hong
4 citations
Materials
Heat Transfer and Boiling Studies
0.85
article

Effects of Pressure, Surfactant Concentration, and Heat Flux on Pool Boiling Using Expanding Microchanneled Surface for Two-Phase Immersion Cooling

Dengwei Fu, Chaobin Dang, Yifei Hu, Sihui Hong
article en
4 citations

Abstract

Deionized water is replacing fluorinated liquids as the preferred choice for two-phase immersion cooling in data centers. Yet, insufficient bubble removal capability at low saturated pressure is a key challenge hindering the widespread application. To solve this issue, this study employs non-ionic surfactant (Tween 20) and asymmetric structures (expanding microchannel) to enhance the boiling performances of deionized water under sub-atmospheric pressure. The research examines the effects of pressure (8.8~38.5 kPa), surfactant concentration (0.1~0.5 mL/L), and heat flux density (10~180 W/cm<sup>2</sup>) on the boiling heat transfer characteristics and analyzes the mechanism of unusual temperature oscillations induced by surfactants. It was found that the trade-off between the sub-atmospheric pressure, surface tension coefficient, and reduced static contact angle results in pronounced intermittent boiling on the heated surface. Even with the addition of surfactants, the improvement in heat transfer requires demanding conditions. Boiling enhancement throughout all heat flux conditions was achieved when the surfactant concentration was higher than 0.2 mL/L for the expanding microchanneled surface. The heat transfer coefficient reached 6.89 W·cm<sup>-2</sup>·K<sup>-1</sup> under 8.8 kPa, which was 45% higher than without the surfactant. Under the same heat flux and sub-atmospheric pressure, as the concentration increased from 0.1 to 0.5 mL/L, the amplitudes of temperature fluctuation of the plane surface and expanding microchanneled surface decreased from 10 K to 2 K and 18 K to 1 K, respectively. The onset of nucleate boiling and wall superheat of the expanding microchanneled surface gradually decreased with the increase in surfactant concentration, where the onset of nucleate boiling decreased by 10.54 K. When the heat flux is 160 W/cm<sup>2</sup>, the wall superheat is reduced by 12.8 K.

MaterialsVol. 17(21)
University of Fukui (JP), Sun Yat-sen University (CN), Zhejiang University (CN)
National Key Research and Development Program of China, Basic and Applied Basic Research Foundation of Guangdong Province
Clean water and sanitation
Openalex Percentile: Top 30%
Heat Transfer and Boiling Studies
0.85
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.