Ensemble LVQ Model for Photovoltaic Line-to-Line Fault Diagnosis Using K-Means Clustering and AdaGrad

Line-to-line (LL) faults are one of the most frequent short-circuit conditions in photovoltaic (PV) arrays which are conventionally detected and cleared by overcurrent protection devices (OCPDs). However, OCPDs are shown to face challenges when detecting LL faults under critical detection conditions, i.e., low mismatch levels and/or high fault impedance values. This occurs due to insufficient fault current, thus leaving the LL faults undetected and leading to power losses and even catastrophic fire hazards. To compensate for OCPD deficiencies, recent studies have proposed modern artificial intelligence (AI)-based methods. However, various limitations can still be witnessed even in AI-based methods, such as (i) most of the models requiring a massive training dataset, (ii) critical fault detection conditions not being taken into consideration, (iii) models not being accurate enough when dealing with critical conditions, etc. To this end, the present paper proposes a learning vector quantization (LVQ)-based ensemble learning model in which three LVQs are individually trained to detect and classify LL faults in PV arrays. The initial LVQ vectors are determined using the k-means clustering method, and the learning rate is optimized by the adaptive gradient (AdaGrad) optimizer. The training and testing datasets are collected according to the PV array’s current–voltage (I–V) characteristic curve, and several features are extracted based on the Canberra and chi-squared distance techniques. The model utilizes a small training dataset, considers various critical detection conditions for LL faults—such as different mismatch levels and fault impedance values—and the final experimental results show that the model achieves an impressive average accuracy of 99.26%.

Authors

Institutions

Publication Details

Journal
Energies
Published
2024-10-23
DOI
https://doi.org/10.3390/en17215269
Citations
7
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ensemble LVQ Model for Photovoltaic Line-to-Line Fault Diagnosis Using K-Means Clustering and AdaGrad

Mohammadreza Aghaei, Parviz Parvin, Amir Nedaei, Aref Eskandari et al.
7 citations
Energies
Photovoltaic System Optimization Techniques
0.72
article

Ensemble LVQ Model for Photovoltaic Line-to-Line Fault Diagnosis Using K-Means Clustering and AdaGrad

Mohammadreza Aghaei, Parviz Parvin, Amir Nedaei, Aref Eskandari, Peyman Ghaedi, Morteza Habibi
article en
7 citations

Abstract

Line-to-line (LL) faults are one of the most frequent short-circuit conditions in photovoltaic (PV) arrays which are conventionally detected and cleared by overcurrent protection devices (OCPDs). However, OCPDs are shown to face challenges when detecting LL faults under critical detection conditions, i.e., low mismatch levels and/or high fault impedance values. This occurs due to insufficient fault current, thus leaving the LL faults undetected and leading to power losses and even catastrophic fire hazards. To compensate for OCPD deficiencies, recent studies have proposed modern artificial intelligence (AI)-based methods. However, various limitations can still be witnessed even in AI-based methods, such as (i) most of the models requiring a massive training dataset, (ii) critical fault detection conditions not being taken into consideration, (iii) models not being accurate enough when dealing with critical conditions, etc. To this end, the present paper proposes a learning vector quantization (LVQ)-based ensemble learning model in which three LVQs are individually trained to detect and classify LL faults in PV arrays. The initial LVQ vectors are determined using the k-means clustering method, and the learning rate is optimized by the adaptive gradient (AdaGrad) optimizer. The training and testing datasets are collected according to the PV array’s current–voltage (I–V) characteristic curve, and several features are extracted based on the Canberra and chi-squared distance techniques. The model utilizes a small training dataset, considers various critical detection conditions for LL faults—such as different mismatch levels and fault impedance values—and the final experimental results show that the model achieves an impressive average accuracy of 99.26%.

EnergiesVol. 17(21)
Amirkabir University of Technology (IR), University of Freiburg (DE), Norwegian University of Science and Technology (NO), Iran University of Science and Technology (IR)
Openalex Percentile: Top 35%
Photovoltaic System Optimization Techniques
0.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.