Hapten Synthesis, Antibody Generation, and Immunoassay Development for Linezolid Therapeutic Monitoring

Linezolid (LNZ) is a broad-spectrum antibiotic used for the treatment of severe Gram+ infections. Significant pharmacokinetic variability in different groups of patients requires therapeutic drug monitoring (TDM) to ensure optimal therapy. This article presents the first description of the development of immunoanalytical TDM systems for LNZ. Four LNZ derivatives (H1-H4) with spacer arms of a different length (0-6.2-9.4-11.8 Å) and chemistry (aliphatic and heterocyclic) were synthesized to prepare H1-H3-immunogens and H1/H4-coating antigens or H1/H2-enzyme tracers. Three distinct antibody types against H1-H3 haptens were generated in rabbits and served as the basis for the development of ELISAs in heterologous coated antigen and coated antibody formats. The length of the spacer in the immunogen had an insignificant effect on the quality of the antibody generated or the performance of the designed coated antibody-ELISA formats (IC<sub>50</sub> = 0.48-0.75 ng/mL) and coated antigen ELISAs (IC<sub>50</sub> = 11.5-28.3 ng/mL). The coated antigen-based assays were considered more appropriate for monitoring therapeutic levels of LNZ due to their more convenient reduced sensitivity but wider dynamic range than the coated antibody-based assays (2.0-160 vs 0.16-2.1 ng/mL). The best recovery of LNZ (82.1-99.6%) from spiked human serum among the sample pretreatments examined was provided by the trichloroacetic acid deproteinization procedure. Serum samples derived from surgical patients with superimposed Gram-positive infections treated with LNZ were evaluated by parallel ELISAs using different immunoreagents. The results obtained in the various assays were found to be concordant, thereby confirming the reliability of the measurements and the developed assay systems suitable for TDM purposes.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-10-23
DOI
https://doi.org/10.1021/acs.analchem.4c04537
Citations
9
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
4.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hapten Synthesis, Antibody Generation, and Immunoassay Development for Linezolid Therapeutic Monitoring

Inna A. Galvidis, Alexander S. Tikhomirov, Yury A. Surovoy, Maksim A. Burkin
9 citations
Analytical Chemistry
Antibiotics Pharmacokinetics and Efficacy
4.03
article

Hapten Synthesis, Antibody Generation, and Immunoassay Development for Linezolid Therapeutic Monitoring

Inna A. Galvidis, Alexander S. Tikhomirov, Yury A. Surovoy, Maksim A. Burkin
article en
9 citations

Abstract

Linezolid (LNZ) is a broad-spectrum antibiotic used for the treatment of severe Gram+ infections. Significant pharmacokinetic variability in different groups of patients requires therapeutic drug monitoring (TDM) to ensure optimal therapy. This article presents the first description of the development of immunoanalytical TDM systems for LNZ. Four LNZ derivatives (H1-H4) with spacer arms of a different length (0-6.2-9.4-11.8 Å) and chemistry (aliphatic and heterocyclic) were synthesized to prepare H1-H3-immunogens and H1/H4-coating antigens or H1/H2-enzyme tracers. Three distinct antibody types against H1-H3 haptens were generated in rabbits and served as the basis for the development of ELISAs in heterologous coated antigen and coated antibody formats. The length of the spacer in the immunogen had an insignificant effect on the quality of the antibody generated or the performance of the designed coated antibody-ELISA formats (IC<sub>50</sub> = 0.48-0.75 ng/mL) and coated antigen ELISAs (IC<sub>50</sub> = 11.5-28.3 ng/mL). The coated antigen-based assays were considered more appropriate for monitoring therapeutic levels of LNZ due to their more convenient reduced sensitivity but wider dynamic range than the coated antibody-based assays (2.0-160 vs 0.16-2.1 ng/mL). The best recovery of LNZ (82.1-99.6%) from spiked human serum among the sample pretreatments examined was provided by the trichloroacetic acid deproteinization procedure. Serum samples derived from surgical patients with superimposed Gram-positive infections treated with LNZ were evaluated by parallel ELISAs using different immunoreagents. The results obtained in the various assays were found to be concordant, thereby confirming the reliability of the measurements and the developed assay systems suitable for TDM purposes.

Analytical ChemistryVol. 96(44)
University College Hospital (GB), Gause Institute of New Antibiotics Russian Academy of Medical Sciences (RU), Research Institute of Vaccines and Sera. Mechnikov of the Russian Academy of Medical Sciences (RU), University College London (GB)
Openalex Percentile: Top 6%
Antibiotics Pharmacokinetics and Efficacy
4.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.