Corrosion effects on flexural behaviour of EPS sandwich concrete panels: a study using acoustic emission technique

The experimental research utilized expanded polystyrene (EPS) panels sized at 1300 × 600 × 130 mm (length × width × thickness) and induced with corrosion via an impressed current method. Varied extents of corrosion were applied for 120, 240, 360, and 480 h, resulting in mass loss percentages of 6.67%, 8.41%, 10.76%, and 18.13% of reinforcement in different panels. The flexural testing along with acoustic emission (AE) monitoring were performed for evaluation of EPS panels. Results obtained defend the correlation of AE energy with the load energy in the EPS panels. The AE parameters of rise angle and average frequency assist in distinguishing between tensile and shear crack types. The energy released during tensile crack formation in EPS panels is minimal compared to that during shear crack formation. These findings are a basis for further AE investigations into EPS panels and developing AE sensor-based methods for identifying corrosion-induced degradation in EPS panels within structures.

Authors

Institutions

Publication Details

Journal
Canadian Journal of Civil Engineering
Published
2024-10-23
DOI
https://doi.org/10.1139/cjce-2024-0128
Citations
1
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrosion effects on flexural behaviour of EPS sandwich concrete panels: a study using acoustic emission technique

Anil Garhwal, Shruti Sharma, A.B. Danie Roy
1 citations
Canadian Journal of Civil Engineering
Concrete Corrosion and Durability
0.26
article

Corrosion effects on flexural behaviour of EPS sandwich concrete panels: a study using acoustic emission technique

Anil Garhwal, Shruti Sharma, A.B. Danie Roy
article en
1 citations

Abstract

The experimental research utilized expanded polystyrene (EPS) panels sized at 1300 × 600 × 130 mm (length × width × thickness) and induced with corrosion via an impressed current method. Varied extents of corrosion were applied for 120, 240, 360, and 480 h, resulting in mass loss percentages of 6.67%, 8.41%, 10.76%, and 18.13% of reinforcement in different panels. The flexural testing along with acoustic emission (AE) monitoring were performed for evaluation of EPS panels. Results obtained defend the correlation of AE energy with the load energy in the EPS panels. The AE parameters of rise angle and average frequency assist in distinguishing between tensile and shear crack types. The energy released during tensile crack formation in EPS panels is minimal compared to that during shear crack formation. These findings are a basis for further AE investigations into EPS panels and developing AE sensor-based methods for identifying corrosion-induced degradation in EPS panels within structures.

Canadian Journal of Civil EngineeringVol. 52(2)
Thapar Institute of Engineering & Technology (IN)
Affordable and clean energy
Openalex Percentile: Top 44%
Concrete Corrosion and Durability
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Corrosion effects on flexural behaviour of EPS sandwich concrete panels: a study using acoustic emission technique — Anil Garhwal, Shruti Sharma, et al. · Canadian Journal of Civil Engineering (2024) | TGRS Research Map | TGRS