High-Precision Diameter Detector for Nuclear Power Main Water Supply System Pipelines

In this paper, a high-precision technique for detecting the inner diameter of pipes in the two-loop main feedwater system of pressurized water reactor (PWR) nuclear power plants is proposed, which realizes the accurate detection of the inner diameter of the pipes. Based on the original measurement data, we establish a reference coordinate system and obtain the coordinates of measuring points on the inner wall of the pipe through coordinate transformation. Based on the original data, the reference coordinate system is established, and the coordinates of the measuring points on the inner wall of the pipe are obtained through coordinate transformation. These coordinates, combined with the shape of the inner wall of the pipe, are used to construct a three-dimensional model of the pipe to be measured, allowing us to determine its inner diameter. In addition, based on the proposed diameter detection technology, we have developed the ARE360 diameter detector for pipe measurement and calibrated the offset center of the ranging using the Whale Optimization Algorithm. Finally, the usability and accuracy of the detector are experimentally verified. The experimental results demonstrate that the developed pipeline internal diameter detection equipment can accurately measure the internal diameter of the pipeline of the two-loop main feedwater system of a PWR nuclear power plant.

Authors

Institutions

Publication Details

Journal
Journal of Surveying Engineering
Published
2024-10-23
DOI
https://doi.org/10.1061/jsued2.sueng-1524
Citations
1
Primary Topic
Advanced Measurement and Detection Methods
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Precision Diameter Detector for Nuclear Power Main Water Supply System Pipelines

Pai Pan, Jianguo Zhou, Jian Yu, Cheng Xing et al.
1 citations
Journal of Surveying Engineering
Advanced Measurement and Detection Methods
0.21
article

High-Precision Diameter Detector for Nuclear Power Main Water Supply System Pipelines

Pai Pan, Jianguo Zhou, Jian Yu, Cheng Xing, Peng Yang, Yaming Xu
article en
1 citations

Abstract

In this paper, a high-precision technique for detecting the inner diameter of pipes in the two-loop main feedwater system of pressurized water reactor (PWR) nuclear power plants is proposed, which realizes the accurate detection of the inner diameter of the pipes. Based on the original measurement data, we establish a reference coordinate system and obtain the coordinates of measuring points on the inner wall of the pipe through coordinate transformation. Based on the original data, the reference coordinate system is established, and the coordinates of the measuring points on the inner wall of the pipe are obtained through coordinate transformation. These coordinates, combined with the shape of the inner wall of the pipe, are used to construct a three-dimensional model of the pipe to be measured, allowing us to determine its inner diameter. In addition, based on the proposed diameter detection technology, we have developed the ARE360 diameter detector for pipe measurement and calibrated the offset center of the ranging using the Whale Optimization Algorithm. Finally, the usability and accuracy of the detector are experimentally verified. The experimental results demonstrate that the developed pipeline internal diameter detection equipment can accurately measure the internal diameter of the pipeline of the two-loop main feedwater system of a PWR nuclear power plant.

Journal of Surveying EngineeringVol. 151(1)
Wuhan University of Technology (CN), Institute of Geodesy and Geophysics (CN), Wuhan University of Science and Technology (CN), Hubei University of Technology (CN)
Clean water and sanitation
Openalex Percentile: Top 47%
Advanced Measurement and Detection Methods
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

High-Precision Diameter Detector for Nuclear Power Main Water Supply System Pipelines — Pai Pan, Jianguo Zhou, et al. · Journal of Surveying Engineering (2024) | TGRS Research Map | TGRS