The Use of 3D Model Printing for Acute Planning in Oral and Maxillofacial Traumatology

Introduction Due to the complex anatomy of craniomaxillofacial structures, facial reconstruction following high-impact traumas is extremely challenging. Therefore, this study aimed to evaluate the use of biomodels in the surgical planning of complex fractures and the sequelae in the oromaxillofacial region. Materials and Methods This is a cross-sectional, exploratory, descriptive, and quantitative documentary study. It was conducted at the “Dom Luiz Gonzaga Fernandes” Emergency and Trauma Hospital, in the hinterland of the state of Paraíba, in Brazil, based on cases recorded between November 2021 and November 2022. The research instrument utilized was a self-developed questionnaire. Results No statistically significant correlation was observed between the biomodel acquisition time and the length of hospitalization, with a Spearman's correlation coefficient of r = -0.079. Although the need for adjustment of osteosynthesis material was 50% in cases where acrylonitrile butadiene styrene (ABS) models were used, with p (1) = 0.464, in order to be significantly more faithful, it would require a study with a higher sample size. The average length of surgery, in minutes, was 91.25 ± 28.00. The average cost of the materials used to manufacture the biomodels, in Brazilian reais (R$), was R$122.00 ± R$89.09. Conclusion The use of biomodels in the surgical planning of complex fractures and oromaxillofacial sequelae did not increase the length of hospitalization. The material used for the prototype manufacture suggests a potential influence on its faithfulness. The length of surgery was shorter in interventions that utilized biomodels in the planning phase. It was also noted that the average cost of manufacture varies according to the type of material chosen and the quantity required.

Authors

Institutions

Publication Details

Journal
The Open Dentistry Journal
Published
2024-10-23
DOI
https://doi.org/10.2174/0118742106326414240910111024
Citations
2
Primary Topic
Anatomy and Medical Technology
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Use of 3D Model Printing for Acute Planning in Oral and Maxillofacial Traumatology

Mário César Furtado da Costa, Joana de Ângelis Alves Silva, Emanuel Sávio de Souza Andrade, Ketinlly Yasmyne Nascimento Martins et al.
2 citations
The Open Dentistry Journal
Anatomy and Medical Technology
0.37
article

The Use of 3D Model Printing for Acute Planning in Oral and Maxillofacial Traumatology

Mário César Furtado da Costa, Joana de Ângelis Alves Silva, Emanuel Sávio de Souza Andrade, Ketinlly Yasmyne Nascimento Martins, Carlos Augusto Pereira do Lago, Gustavo José de Luna Campos, Rebeca Valeska Soares Pereira
article en
2 citations

Abstract

Introduction Due to the complex anatomy of craniomaxillofacial structures, facial reconstruction following high-impact traumas is extremely challenging. Therefore, this study aimed to evaluate the use of biomodels in the surgical planning of complex fractures and the sequelae in the oromaxillofacial region. Materials and Methods This is a cross-sectional, exploratory, descriptive, and quantitative documentary study. It was conducted at the “Dom Luiz Gonzaga Fernandes” Emergency and Trauma Hospital, in the hinterland of the state of Paraíba, in Brazil, based on cases recorded between November 2021 and November 2022. The research instrument utilized was a self-developed questionnaire. Results No statistically significant correlation was observed between the biomodel acquisition time and the length of hospitalization, with a Spearman's correlation coefficient of r = -0.079. Although the need for adjustment of osteosynthesis material was 50% in cases where acrylonitrile butadiene styrene (ABS) models were used, with p (1) = 0.464, in order to be significantly more faithful, it would require a study with a higher sample size. The average length of surgery, in minutes, was 91.25 ± 28.00. The average cost of the materials used to manufacture the biomodels, in Brazilian reais (R$), was R$122.00 ± R$89.09. Conclusion The use of biomodels in the surgical planning of complex fractures and oromaxillofacial sequelae did not increase the length of hospitalization. The material used for the prototype manufacture suggests a potential influence on its faithfulness. The length of surgery was shorter in interventions that utilized biomodels in the planning phase. It was also noted that the average cost of manufacture varies according to the type of material chosen and the quantity required.

The Open Dentistry JournalVol. 18(1)
Universidade Estadual da Paraíba (BR), Universidade de Pernambuco (BR)
Good health and well-being
Openalex Percentile: Top 43%
Anatomy and Medical Technology
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.