Imaging Nanoscale Electronic Changes in a Biased GaN HEMT

Abstract The transmission electron microscope (TEM) is the standard high-resolution technique for imaging microelectronics. But TEM primarily generates contrast related to the physical structure and composition of samples, giving little insight into their electronic properties. Samples must also be electron transparent, typically requiring cross-sectioning of components to nanometers-thin foils prior to imaging, which can compromise their electronic integrity. These cross section samples are also notoriously difficult to electrically connect to without surface leakage dominating transport. As a result, successful in situ electronic testing or bias-manipulation of electronic devices in the TEM is notably rare. Here we image nanoscale, bias-induced electronic changes in an electrically contacted cross section extracted from a GaN high electronmobility transistor (HEMT). The sample is prepared using a Xe+-based plasma focused ion beam (PFIB) to eliminate conducting implantation of the standard FIB ion, Ga+. Scanning TEM electron beam-induced current (STEM EBIC) imaging visualizes bias-induced changes to the device’s electronic structure during normal biasing, stressing, and after failure, all performed in situ.

Authors

Institutions

Publication Details

Journal
Proceedings - International Symposium for Testing and Failure Analysis
Published
2024-10-23
DOI
https://doi.org/10.31399/asm.cp.istfa2024p0317
Primary Topic
GaN-based semiconductor devices and materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Imaging Nanoscale Electronic Changes in a Biased GaN HEMT

William A. Hubbard, B. C. Regan
Proceedings - International Symposium for Testing and Failure Analysis
GaN-based semiconductor devices and materials
article

Imaging Nanoscale Electronic Changes in a Biased GaN HEMT

William A. Hubbard, B. C. Regan
article en

Abstract

Abstract The transmission electron microscope (TEM) is the standard high-resolution technique for imaging microelectronics. But TEM primarily generates contrast related to the physical structure and composition of samples, giving little insight into their electronic properties. Samples must also be electron transparent, typically requiring cross-sectioning of components to nanometers-thin foils prior to imaging, which can compromise their electronic integrity. These cross section samples are also notoriously difficult to electrically connect to without surface leakage dominating transport. As a result, successful in situ electronic testing or bias-manipulation of electronic devices in the TEM is notably rare. Here we image nanoscale, bias-induced electronic changes in an electrically contacted cross section extracted from a GaN high electronmobility transistor (HEMT). The sample is prepared using a Xe+-based plasma focused ion beam (PFIB) to eliminate conducting implantation of the standard FIB ion, Ga+. Scanning TEM electron beam-induced current (STEM EBIC) imaging visualizes bias-induced changes to the device’s electronic structure during normal biasing, stressing, and after failure, all performed in situ.

Proceedings - International Symposium for Testing and Failure AnalysisVol. 84918
University of California, Los Angeles (US)
Openalex Percentile: Top 89%
GaN-based semiconductor devices and materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.