Targeted TEM SRAM-Like Analysis Without Delayering

Abstract In the ever-increasing complexity of today’s state-of-the-art semiconductor structures, it is desirable to seek any advantage in the fault isolation and analysis paradigm to improve time to data. This paper discusses one such improvement where it is shown to be possible to target silicon (Si) devices, their metal contacts, or any other location in the wafer stack in a SRAM test structure from metal level 7 (M7) for transmission electron microscopy (TEM) sample fabrication using a modified sample geometry, focused ion beam (FIB) software targeting tools, and planning for failure analysis at the mask design stage. Electron beam inspection data was used to drive back to the location of interest in this example. The subsequent analysis shows a silicon and oxygen rich material creating an open contact defect signature.

Authors

Institutions

Publication Details

Journal
Proceedings - International Symposium for Testing and Failure Analysis
Published
2024-10-23
DOI
https://doi.org/10.31399/asm.cp.istfa2024p0079
Primary Topic
Integrated Circuits and Semiconductor Failure Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Targeted TEM SRAM-Like Analysis Without Delayering

J. Demarest, Brad Austin, L. Tierney, Z. Martin
Proceedings - International Symposium for Testing and Failure Analysis
Integrated Circuits and Semiconductor Failure Analysis
article

Targeted TEM SRAM-Like Analysis Without Delayering

J. Demarest, Brad Austin, L. Tierney, Z. Martin
article en

Abstract

Abstract In the ever-increasing complexity of today’s state-of-the-art semiconductor structures, it is desirable to seek any advantage in the fault isolation and analysis paradigm to improve time to data. This paper discusses one such improvement where it is shown to be possible to target silicon (Si) devices, their metal contacts, or any other location in the wafer stack in a SRAM test structure from metal level 7 (M7) for transmission electron microscopy (TEM) sample fabrication using a modified sample geometry, focused ion beam (FIB) software targeting tools, and planning for failure analysis at the mask design stage. Electron beam inspection data was used to drive back to the location of interest in this example. The subsequent analysis shows a silicon and oxygen rich material creating an open contact defect signature.

Proceedings - International Symposium for Testing and Failure AnalysisVol. 84918
IBM (United States) (US), Thermo Fisher Scientific (United States) (US)
Openalex Percentile: Top 84%
Integrated Circuits and Semiconductor Failure Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.