Nitrogen Vacancy Quantum Sensing for Current Density Imaging with Sub 30 nm Resolution

Abstract Non-destructive failure analysis is often limited by the sensitivity or the resolution of the method utilized, making state-of-the-art integrated circuits difficult to analyze. Here, we present a powerful method for surface failure analysis, based on scanning a single Nitrogen Vacancy center over the sample. This results in quantitative current density maps with high sensitivity and sub-30 nm resolution, detecting for example, open and short circuits and visualizing the current flow. We demonstrate the technology by mapping current flow through device structures separated by gaps as low as 30 nm. We further show how resolution is reduced as a capping layer is added, by measuring at a fixed offset of 30 nm from the surface.

Authors

Publication Details

Journal
Proceedings - International Symposium for Testing and Failure Analysis
Published
2024-10-23
DOI
https://doi.org/10.31399/asm.cp.istfa2024p0217
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nitrogen Vacancy Quantum Sensing for Current Density Imaging with Sub 30 nm Resolution

S. Josephy, B. Josteinsson, Andrea Morales, Götz P. Hellmann
Proceedings - International Symposium for Testing and Failure Analysis
Analytical Chemistry and Sensors
article

Nitrogen Vacancy Quantum Sensing for Current Density Imaging with Sub 30 nm Resolution

S. Josephy, B. Josteinsson, Andrea Morales, Götz P. Hellmann
article en

Abstract

Abstract Non-destructive failure analysis is often limited by the sensitivity or the resolution of the method utilized, making state-of-the-art integrated circuits difficult to analyze. Here, we present a powerful method for surface failure analysis, based on scanning a single Nitrogen Vacancy center over the sample. This results in quantitative current density maps with high sensitivity and sub-30 nm resolution, detecting for example, open and short circuits and visualizing the current flow. We demonstrate the technology by mapping current flow through device structures separated by gaps as low as 30 nm. We further show how resolution is reduced as a capping layer is added, by measuring at a fixed offset of 30 nm from the surface.

Proceedings - International Symposium for Testing and Failure AnalysisVol. 84918
Openalex Percentile: Top 81%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.